MACHINE CONTROL PANEL (L38, L33 & L28)
Circuit Breakers (See Figure #2, Item "K"-"P")
The circuit breaker reset buttons are located on the rear cover, below the control handle. The breakers are
located as follows:
If a circuit breaker trips, determine which motor is not operating and turn the key switch "OFF". Wait five
minutes and push the reset button back in. Turn the key switch "on" and try again. Contact an authorized
service person if the breaker trips again.
Page
-12-
Item K & L - Brush Motors (35A)
Item M - Traverse Motor (30A)
Item N - Vac Motor (25A)
Item O - Actuator Motor, Brush Head (5A)
Item P - Actuator Motor, Squeegee (1.5 Amp)
E
I
J
P
O
N
Figure #3
CLARKE TECHNOLOGY Operator's Manual -Encore S28/L28/S33/L33/S38/L38
G
C
F H
D
B
A
M
L
K
Figure #2
Figure #4