Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
The appliance is not
The unit is not switched
working
on
Plug and lead are
damaged
Fuse in the plug has
blown
Power supply
Internal wiring fault
The appliance turns
Too much ice on the
on, but the
evaporator
temperature is too
Condenser blocked with
high/low
dust
Doors are not shut
properly
Appliance is located near
a heat source or air flow
to the condenser is being
interrupted
Ambient temperature is
too high
Unsuitable foodstuffs are
being stored in the
appliance
Appliance is overloaded
The appliance is
The appliance is not
leaking water
properly levelled
The discharge outlet is
blocked
Movement of water to the
drain is obstructed
The water container is
damaged
The appliance is
Loose nut/screw
unusually loud
The appliance has not
been installed in a level or
stable position
Probable Cause
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Call POLAR agent or qualified Technician
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Check and tighten all nuts and screws
Check installation position and change if necessary
Action