Cleaning, Care & Maintenance
1. Before cleaning always disconnect the Multideck Refrigerator from the electricity supply.
2. Clean using either warm soapy water, or a suitable antibacterial cleaning agent, dry thoroughly before
reconnecting the electricity supply.
3. Do not use abrasive or corrosive cleaning agents.
Cleaning the Condenser
Your Polar Multideck Refrigerator will benefit from having the condenser cleaned at regular intervals, your
Polar service agent will be able to carry this out for you.
Operating outside of the recommend temperature range and placing next to a heat source
will also increase the amount of ice and internal/external condensation. If external
condensation occurs wipe the surface down with a cloth.
Excessive ice will result in longer running times that will increase energy consumption and
increase the deterioration of components.

Troubleshooting

A qualified technician must carry out repairs if required.
Fault
The appliance is not
working
Poor refrigeration
performance
Showcase is noisy
when turned on
Fault Code def
Fault Code HI
Fault Code LO
Fault Code E1
Fault Code E2
Probable Cause
The unit is not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
High ambient temperature
Poor ventilation
Too much food in the Showcase
is preventing cold air circulating
Condenser needs to be cleaned
Multideck is not level
Multideck is too close to a wall or
other object
Defrost Cycle in progress
Internal temperature has risen
above set temperature.
Internal temperature has
dropped below set temperature
Air Probe Failure
Failure has occurred to the
evaporator probe
Solution
Check the unit is plugged in correctly and
switched on
Replace Plug or Lead
Replace the fuse
Check mains power supply
Ventilate
room or area around Multideck
Increase air flow around multideck
Take out some food
Consult a qualified Technician
Adjust position to level
Move position
No action required
Ensure all grills and ventilation are not
obstructed. Pull down the shutter for 1
hour. IF unit still reads HI call for service
If this persists call for service
Remove stock and switch off unit. Failure
to do so may further damage the unit.
Call for service
Call for service