Shutting Down And Removing A Fortigate-5001B Board - Fortinet FortiGate-5001B Manual

Table of Contents

Advertisement

Hardware installation

Shutting down and removing a FortiGate-5001B board

FortiGate-5001B Security System Guide
01-400-134818-20120216
http://docs.fortinet.com/
8 Turn both handles to their fully-closed positions.
The handles should hook into the sides of the chassis slot. Closing the handles draws
the FortiGate-5001B board into place in the chassis slot and into full contact with the
chassis backplane. The FortiGate-5001B front panel should be in contact with the
chassis front panel and both handles should lock into place.
As the handles closed power is supplied to the board. If the chassis is powered on the
IPM LED starts flashing blue. If the board is aligned correctly, inserted all the way into
the slot, and the handles are properly closed the IPM LED flashes blue for a few
seconds. At the same time the STATUS LED flashes green, the interface LEDs flash
amber, and the ACC LED starts flashing green. After a few seconds the IPM LED goes
out and the FortiGate-5001B firmware starts up. During start up the STATUS LED may
continue to flash green. Once the board has started up and is operating correctly, the
front panel LEDs are lit as described in
Table 6: FortiGate-5001B normal operating LEDs
LED
OOS
PWR
STA
ACC
IPM
If the board has not been inserted properly the IPM LED changes to solid blue and all
other LEDS turn off. If this occurs, open the handles, slide the board part way out, and
repeat the insertion process.
9 Once the board is inserted correctly, fully tighten the retention screws to lock the
FortiGate-5001B board into position in the chassis slot.
Tighten
The following procedure describes how to correctly use the FortiGate-5001B mounting
components described in
remove a FortiGate-5001B board from an ATCA chassis slot.
To avoid potential hardware problems, always shut down the FortiGate-5001B operating
system (FortiOS) properly before power cycling the FortiGate-5001B board.
Shutting down and removing a FortiGate-5001B board
Table
State
Off
Green
Off
Off (Or flashing green when the system accesses the
FortiGate-5001B flash disk.)
Off
Retention
Screw
"FortiGate-5001B mounting components" on page 14