Electrolux ENV06 Service Manual page 41

Hide thumbs Also See for ENV06:
Table of Contents

Advertisement

Alarm
Door lock unit faulty; Wiring faulty;
E42
PCB faulty.
Door lock unit faulty; Wiring faulty;
E43
PCB faulty.
E44
PCB faulty.
E45
PCB faulty.
E51
PCB faulty; current leakage from motor or from wiring.
E52
Motor faulty; wiring faulty; PCB faulty.
E53
PCB faulty.
E54
PCB faulty; current leakage from motor or from wiring.
E57
Wiring defective on inverter for motor, inverter board defective.
Wiring defective on inverter for motor, inverter board defective, abnormal motor
E58
operation (motor overloaded); Motor defective.
Motor defective; Wiring defective on inverter for motor;
E59
Inverter board defective.
Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let appliance
E5A
cool down).
E5H
Wiring defective, Inverter board defective.
Inverter board defective, the masters voltage is too high (measure the masters
E5C
voltage).
E5d
Line interference, Wiring defective, defective main board or inverter board.
Defective wiring between main board and inverter board, Defective inverter board,
E5E
defective main board.
E5F
Defective inverter board, Defective wiring, defective main board.
E61
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
E62
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
E66
PCB faulty.
E68
Earth-leakage between heater and earth.
SOI/DT 2007-10 dmm
Possible fault
41/48
Action/machine status
Cycle is paused.
(Safety drain cycle) Cycle stops.
(Safety drain cycle) Cycle stops.
(Safety drain cycle) Cycle stops.
Cycle blocked, door locked (after 5
attempts).
Cycle blocked, door locked (after 5
attempts).
Cycle blocked, door locked.
Cycle blocked, door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops with door locked (after 5
attempts).
Cycle stops
Cycle stops with door locked (after 5
attempts).
The heating phase is skipped.
Safety drain cycle – Cycle stopped
with door open.
Safety drain cycle – Cycle stopped
with door open.
Cycle blocked with door open.
Reset
START/RESET
ON/OFF RESET
ON/OFF RESET
ON/OFF RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
RESET
ON/OFF
RESET
START/RESET
RESET
RESET
RESET
599 70 27-90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents