22. Position the shoulder screw removed in Step 13 through the actuator block and into the
base of the lift platform.
23. Tighten the shoulder screw that connects the actuator shaft and actuator block to the lift
platform.
24. Position the switch actuator on the top of the actuator shaft.
25. Replace the screw that secures the switch actuator to the actuator shaft.
26. If you must replace one or more of the limit switches...
THEN...
Continue with the next step to
replace the upper limit switch, skip
to step 31 to replace the down
limit switch or skip to Step 35 to
replace the zero sense switch.
Replacing the Upper Lift Limit Switch
27. Position the limit switch at its mounting location.
28. Replace the screws and washers that secure the limit switch to the switch bracket.
29. Connect the red wires disconnected in Step 3 to the limit switch terminals.
30. If you are replacing more than one limit switch...
THEN...
Continue with the next step (to
to replace the down limit switch) or
skip to Step 35 (to replace the zero
sense switch.
Replacing the Down Lift Limit Switch
31. Position the limit switch at its mounting location.
32. Replace the screws and washers that secure the limit switch to the switch bracket.
33. Connect the black wires disconnected in Step 6 to the limit switch terminals.
34. If you are replacing the zero sense switch...
C960 Series Commercial Treadmill
OTHERWISE...
Skip to Step 38.
OTHERWISE...
Skip to Step 38.