Diagram 5.2 - Upper PCA Component Layout
Table 5.1 - Voltage Test Points (Function Keys Not Pressed)
PLACE THE POSITIVE LEAD OF THE
VOLTMETER ON...
Pin 1 of J4
Pin 2 of J4
Pin 3 of J4
Pin 4 of J4
Pin 6 of J4
Pin 7 of J4
Pin 8 of J4
Pin 9 of J4
Pin 4 of J2
Pin 5 of J2
Pin 6 of J2
Table 5.2 - Voltage Test Points (Function Keys Pressed)
Place the positive lead
of the voltmeter on...
Pin 1 of J4
Pin 2 of J4
Pin 3 of J4
Pin 4 of J4
Pin 6 of J4
Pin 7 of J4
Pin 8 of J4
Pin 9 of J4
Pin 4 of J2
Pin 6 of J2
Pin 7 of J2
THE VOLTMETER SHOULD
READ...
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
5 Vdc ± 500 mVdc
At the electronic
console, press...
Left CHANGE key
STOP key
SPEED
key
SPEED
key
QUICK START key
ENTER key
Right CHANGE key
Center CHANGE key
RESET key
INCLINE
key
INCLINE
key
C960 Series Commercial Treadmill
The voltmeter
should read between...
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
0 Vdc and 350 mVdc
Page 29