Adjusting Thread Tension; Pressure Of Presser Foot; Adjusting Position Of Presser Foot - Yamato VF2400 class Instruction Manual

Vf2400 series high speed flat bed interlock stitch machine
Table of Contents

Advertisement

5.4 Adjusting thread tension

Adjust the thread tension with the thread tension spring
caps ① depending on fabric type, thread type, seam width,
stitch length, and other sewing conditions.
● To tighten the thread tension, turn them clockwise.
● To loosen the thread tension, turn them counterclock-
wise.

5.5 Pressure of presser foot

Loosen the lock nut ② and turn the presser spring regula-
tor ③ to adjust the pressure.
● To increase the pressure, turn it clockwise.
● To decrease the pressure, turn it counterclockwise.
Keep the pressure as low as possible for stable sewing per-
formance.

5.6 Adjusting position of presser foot

Before adjusting, ALWAYS turn the power switch OFF
and check that the machine has already stopped.
Adjust left-and-right position of the needle holes of the
presser foot.
Loosen the screw ④ . Move the front of the presser foot
right or left so that the needles drop in the centers of the
needle drops respectively.
Then, tighten the screw ④ securely.
Fig. 5-5
Decrease
Fig. 5-6
Fig. 5-7
17
5. Proper operation
Tighten
Loosen
Increase
Needles
VF2400

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf2403Vf2404Vf2503Vf2504Vf2500Vf2411 ... Show all