Access To The Combustion Chamber; Removing The Combustion Cover; Removing The Burner And Jets; Removing The Electrodes - Ariston microGenus 23 MFFI Servicing Instructions

Hide thumbs Also See for microGenus 23 MFFI:
Table of Contents

Advertisement

1.3
A
CCESS TO THE

Removing the combustion cover

1. Remove the screws "E" (F
2. Lift off the combustion cover.
E
99.tif

Removing the burner and jets

1. Remove the screws "F" from the burner (F
2. Remove the burner (F
IG
3. Remove the jets using a No. 7 socket spanner;
4. Replace in reverse order.
F
. 1.11
IG
12 eps
B063
Supplied By www.heating spares.co Tel. 0161 620 6677
C
C
OMBUSTION
HAMBER
. 1.10);
IG
E
E
F
. 1.10
IG
. 1.11);
IG
. 1.12);
F
F
78 eps

Removing the electrodes

Before carrying out this procedure, unscrew and slide the
burner forward (see previous section).
1. Remove rubber gasket "G" (Fig. 1.13);
2. To remove the detection electrode disconnect the cable
at its connection point close to the P.C.B. (Fig. 1.14);
49 eps
50 eps
Fig. 1.12
F
. 1.13
IG
G
F
. 1.14
IG
5