Sensor System Connection
4.3 Sensor Module Cabinet 10 (SMC10)
DRIVE-CLiQ interface X500
Table 4-2
DRIVE-CLiQ interface X500
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
4-6
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
Reserved, do not use
GND (0 V)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Electronic ground
Equipment Manual for Control Units and Additional System Components