Siemens SINAMICS S120 Equipment Manual page 100

Control units and additional system components
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Sensor System Connection
4.5 Sensor Module Cabinet 30 (SMC30)
DRIVE-CLiQ interface X500
Table 4-13
DRIVE-CLiQ interface X500
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Molex, order number: 85999-3255
X520 sensor connection 1 TTL with open-circuit monitoring
Table 4-14
Sensor connection X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Caution
The sensor power supply can be parameterized to 5 V or 24 V. The sensor may be
destroyed if you enter the wrong parameters.
4-22
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
Reserved, do not use
GND (0 V)
Signal name
Reserved, do not use
Reserved, do not use
Reserved, do not use
P_Encoder 5 V / 24 V
P_Encoder 5 V / 24 V
P_Sense
M_Encoder (M)
Reserved, do not use
M_Sense
R
R*
B*
B
A*
A
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Electronic ground
Technical specifications
Sensor power supply
Sense input sensor power supply
Ground for sensor power supply
Ground sense input
Reference signal R
Inverted reference signal R
Inverted incremental signal B
Incremental signal B
Inverted incremental signal A
Incremental signal A
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents