System Data - Siemens SINAMICS S120 Equipment Manual

Control units and additional system components
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

System Overview

1.7 System data

1.7
System data
Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all
components of the SINAMICS S120 booksize drive system.
Electrical data
Line connection voltage
Line frequency
Electronics power supply
Radio interference suppression
Standard
With line filter
Overvoltage category
*If a motor holding brake is used, restricted tolerances may have to be taken into account.
Mechanical data
Vibratory load
Transportation
Operation
Shock load
Transportation
Operation
Ambient conditions
Degree of protection
Protection class
Type of cooling
Permissible ambient and coolant temperature (air) during
operation for line-side components, line modules and motor
modules
Permissible ambient and coolant temperature (air) during
operation for control units, additional system components,
DC link components and sensor modules
1-10
3 AC 380 V to 480 V ±10 %
(-15 % < 1 min)
47 – 63 Hz
24 V DC, -15/+20 %*
No radio interference suppression
Class A1 to EN 55011
Class III to EN 60 664-1
EN 60 721-3-2, class 2M3
EN 60 721-3-3, class 3M4
EN 60 721-3-2, class 2M3
EN 60 721-3-3, class 3M4
IP 20 to EN 60 529
Class I (with protective conductor system) and
Class III (PELV) to EN 61 800-5-1
Internal ventilator, power sections with increased air cooling
by in-built fans
0 °C to 40 °C without derating,
>40 °C to +55 °C see derating characteristics
0 °C to +55 °C
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0