Siemens SINAMICS S120 Equipment Manual page 101

Control units and additional system components
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Shield brackets for the SMC30 are available from:
Weidmüller: http://www.weidmueller.com
Phönix: http://www.phoenixcontact.com
X521 sensor connection 2 HTL/TTL without open-circuit monitoring
Table 4-15
Sensor connection X521
Pin
1
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm
When unipolar HTL sensors are used, terminal block A*, B*, and R* must be jumpered with M.
X531 sensor connection 2 HTL/TTL without open-circuit monitoring
Table 4-16
Sensor connection X531
Pin
1
2
3
4
5
6
7
8
Max. connectable cross-section: 1.5 mm
Note
Ensure that when the sensor is connected via terminals, the cable shield must be placed on
the module.
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0
Designation
A
A*
B
B*
R
R*
CTRL
M (GND)
2
Designation
P_Encoder 5 V / 24 V
M_Encoder
- Temp
+ Temp
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
2
4.5 Sensor Module Cabinet 30 (SMC30)
Technical specifications
Incremental signal A
Inverted incremental signal A
Incremental signal B
Inverted incremental signal B
Reference signal R
Reference signal R*
Control signal
Ground via inductivity
Technical specifications
Sensor power supply
Ground for sensor power supply
Motor temperature measurement KTY84–1C130
Motor temperature measurement KTY84–1C130
Sensor System Connection
4-23