Siemens SINAMICS S120 Equipment Manual page 27

Control units and additional system components
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Climatic ambient conditions
Storage
Transportation
Operation
Environmental class/harmful chemical substances
Storage
Transportation
Operation
Organic/biological influences
Storage
Transportation
Operation
Degree of contamination
Installation altitude
Approbation
Certification
Safety Integrated – safe standstill (SH) and safe brake
control (SBC)
Modules
Line modules in booksize format
Rated supply voltage
Active line modules in booksize format
Rated pulse frequency
Motor modules in booksize format
DC link connection voltage
Rated pulse frequency
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0
Class 1K3 to EN 60 721-3-1
Temperature -25 °C to +55 °C
Class 2K4 to EN 60 721-3-3
Temperature -40 °C to +70 °C
Max. humidity 95 % at 40 °C
Class 3K3 to EN 60 721-3-3
Relative air humidity 5 to 65 %
Annual average, ≦ 80 % above the maximum for 2 months a
year.
Avoid splashing water and do not allow condensation or ice
to form
(EN 60 204, Part 1)
Class 1C2 to EN 60 721-3-1
Class 2C2 to EN 60 721-3-2
Class 3C2 to EN 60 721-3-3
Class 1B1 to EN 60 721-3-1
Class 2B1 to EN 60 721-3-2
Class 3B1 to EN 60 721-3-3
2 to EN 60 664-1
Up to 1,000 m above sea level without derating,
>1,000 m to 5,000 m above sea level see derating
characteristics
CE (low-voltage and EMC Directives), cULus
(file nos.: E192450, E164110 and E70122)
Safety Integrity Level (SIL) 2 to IEC 61508,
control category 3 to EN 954-1
3AC 380 V
8 kHz
510 V DC to 750 V DC
4 kHz
System Overview
1.7 System data
1-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents