Climatic ambient conditions
Storage
•
Transportation
•
Operation
•
Environmental class/harmful chemical substances
Storage
•
Transportation
•
Operation
•
Organic/biological influences
Storage
•
Transportation
•
Operation
•
Degree of contamination
Installation altitude
Approbation
Certification
Safety Integrated – safe standstill (SH) and safe brake
control (SBC)
Modules
Line modules in booksize format
Rated supply voltage
•
Active line modules in booksize format
Rated pulse frequency
•
Motor modules in booksize format
DC link connection voltage
•
Rated pulse frequency
•
Equipment Manual for Control Units and Additional System Components
Equipment Manual, (GH1), 04.2004 Edition, 6SL3097-2AH00-0BP0
Class 1K3 to EN 60 721-3-1
Temperature -25 °C to +55 °C
Class 2K4 to EN 60 721-3-3
Temperature -40 °C to +70 °C
Max. humidity 95 % at 40 °C
Class 3K3 to EN 60 721-3-3
Relative air humidity 5 to 65 %
Annual average, ≦ 80 % above the maximum for 2 months a
year.
Avoid splashing water and do not allow condensation or ice
to form
(EN 60 204, Part 1)
Class 1C2 to EN 60 721-3-1
Class 2C2 to EN 60 721-3-2
Class 3C2 to EN 60 721-3-3
Class 1B1 to EN 60 721-3-1
Class 2B1 to EN 60 721-3-2
Class 3B1 to EN 60 721-3-3
2 to EN 60 664-1
Up to 1,000 m above sea level without derating,
>1,000 m to 5,000 m above sea level see derating
characteristics
CE (low-voltage and EMC Directives), cULus
(file nos.: E192450, E164110 and E70122)
Safety Integrity Level (SIL) 2 to IEC 61508,
control category 3 to EN 954-1
3AC 380 V
8 kHz
510 V DC to 750 V DC
4 kHz
System Overview
1.7 System data
1-11