Actions To Be Taken For Poe Problems - Alaxala AX6700S series Troubleshooting Manual

Hide thumbs Also See for AX6700S series:
Table of Contents

Advertisement

No.
Items to check
3
For AX6700S, AX6600S, or
AX6300S series switches,
use the
show interfaces
command to display the
failure statistics, and check
whether there is a count for
the following item for the
target port. If there is a
count, see the Cause and
Action columns.
• RF
4
Use the
show interfaces
command to display the
failure statistics, and check
whether there is a count for
the following item for the
target port. If there is a
count, see the Cause and
Action columns.
• Long frames
5
Use the
show qos
command to
queueing
check whether there is a
count for the following item.
If there is a count, see the
Cause and Action columns.
• discard_pkt

3.5.6 Actions to be taken for PoE problems

If a problem such as a disabled power supply unit occurs when PoE is used, isolate the cause of the
problem according to the failure analysis method described in the following table.
Cause
Line quality on
Check the type of the optical fiber. For the types, see the
the sending side
Hardware Instruction Manual.
is degraded.
If an optical attenuator is used, check the attenuation value. For
the optical level, see the Hardware Instruction Manual.
Check the cable length. For the cable length, see the Hardware
Instruction Manual.
Check whether the cables are connected correctly (for
example, check for incomplete insertion). Make sure that the
end sections of the cables are clean. If they are dirty, clean
them.
Check whether the transceiver is connected correctly.
Adjust the transceiver to comply with the segment standard of
the remote device.
Check whether the optical level is correct. For the optical level,
see the Hardware Instruction Manual.
Perform a line test on the Switch and make sure that the
functionality of the sending side has no problem. Check the
results of the
action described in Action. For the test types to be specified,
see 6.1 Testing a line.
Packets
Adjust the jumbo frame settings to those on the remote device.
exceeding the
maximum
allowed frame
length are
received.
Packets are
Check whether drop control and the shaper are being used
discarded.
appropriately in the system configuration.
3. Troubleshooting Functional Failures During Operation
Action
command, and take the
no test interfaces
43