3.3.17 Base Plate
1.
Dismount the upper cover assy. (See Section 3.3.4.)
2.
Dismount the base frame. (See Section 3.3.12).
3.
Remove two screws (1), disconnect connector (2), and dismount power supply unit (3).
4.
Dismount insulation sheet (4).
5.
Remove five screws (5) and dismount main control board (6).
6.
Remove screw (7) , disconnect connector (8) and dismount P6L board (9) from base plate (10).
7.
Dismount insulation sheet (11).
Service Manual for OKIPAGE 8z