6Kq Port Module (6Kpm) Installation; Connecting Management Console Terminal To 6Kqserial - GarettCom Magnum 6KQ Installation And User Manual

Managed field switch
Table of Contents

Advertisement

Magnum 6KQ Managed Field Switch Installation and User Guide
The Alarm Contacts are on the front left area (next to the DC power source)
of the Magnum 6KQ unit and are green in color as shown in the picture.
3.6

6KQ Port Module (6KPM) Installation

Magnum 6KQ Switches are normally received from the factory with all
required 6K Port Modules installed.
NOTE: There may be situations where the 6K PMs need to be added or replaced.
Any change in configuration of the modules can be done only via factory
installation. There is no field upgrade option for 6KQ port modules. Please contact
Tech Support (support@garrettcom.com) / RMA(rma@garrettcom.com) for
changing modules.
The 6KQ port modules are not compatible with or inter-changeable with the other
Magnum 6K-Family Switches' PMs, which use larger (typically 8-port) modules.
3.7
Connecting a Management Console Terminal to Magnum 6KQ
(Serial-RJ-45 Console Port)
8
1
8 pin RJ-45
female connector
at the Magnum
6KQ front panel
Female
connector
www GarrettCom com
.
The serial console port on the Magnum 6KQ is
different from other 6K-family switches. The Serial RJ-
45 port, as shown in the picture, requires an 8-pin RJ-
45 male connector to have the proper communication.
(Note - the serial RJ-45 console port on the Magnum
6KQ is compatible with Cisco-type RJ-45 console port
cables).
The Serial port pin-out for the RJ-45 console port used
on Magnum 6KQ
Pin Name
1
RTS
3
TXD
4
GND Ground
5
GND Ground
6
RXD Receive Data
8
CTS
Pin-out info for 6KQ (RJ-45 female
connector).
.
Description
Request To Send OUT
Transceiver Data OUT
Clear To Send
29
8
1
Dir
8 pin RJ-45
male connector
-
at the cables
-
IN
IN
Male
connector
(04/07)