Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com...
Page 4
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Electrical Safety requirements: This product is to be installed Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like). 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Table of Contents ................Page SPECIFICATIONS ................1 Technical Specifications ..............1 Ordering Information ................4 Introduction .................... 6 Inspecting the Package and Product ............ 6 Product Description - Magnum 6KQ Field Switch ......7 2.2.1...
Page 6
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) 5.2.1a 6KQ2-10ST, 2@10Mb mm FX-ST “twist lock” Module ..36 5.2.2 6KQ2-MSC, 2@100Mb mm FX-SC “snap-in” Module .... 37 5.2.3 6KQ2-SSCL, 2 Ports @100Mbps sm FX-SC-type, Sgl.M ..37 5.2.4 6KQ3-RJMSC, 2@ 10/100RJ-45&1@100Mm FX-SC .....
Page 7
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) THE MAGNUM LINE Industrial networking products "Designed and Manufactured in the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM™ LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY-STANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) SPECIFICATIONS Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.3x full-...
Page 10
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Power Consumption: 35 watts worst case (for a fully loaded fiber model) 12 watts typical (for a small 4 port copper-only model) Dual DC Power Input (Optional) A Dual-Source option is available for the 12VDC, 24VDC, –48VDC, and...
Please use this URL: for the complete Configuration Guide for the Magnum 6KQ. http://www.garrettcom.com/techsupport/insertion_guides/6kqcg.pdf Configuration Options: Each Magnum 6KQ base unit may be configured with a choice of 3 modular slots. Following modules can be configured in Slot B and D (Slot C is 100Mb Fiber only) Magnum 6KQ Port Modules...
Page 12
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Fiber-only Slot C configuration choices “4 ports” module, w/four 100Mb mm 2km FX MTRJ’s fiber ports 6KQF-4MT “4 ports” module, w/four 100Mb mm 2km FX LC’s fiber ports 6KQF-4MLC “4 ports” module, w/four 100Mb Sm, 15km FX LC’s fiber ports 6KQF-4SLC “2 ports”...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Introduction Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery.
Designed for use in industrial applications such as factory floors and control cabinets, industrial video surveillance systems with PoE, power utility substations, tariffed carrier field facilities, or transportation and oil and gas, the rugged Magnum 6KQ handles stressful workloads (mixes of bursty data traffic and priority streaming traffic) as well as harsh environmental conditions.
Page 15
High performance features include non-blocking unicast traffic speed on all ports and 802.1p QoS Traffic Prioritization. Magnum 6KQ switches are “plug-and-play” and are designed for use in connecting edge devices such as PLCs, IEDs and PoE video cameras...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and software through traps, providing a record of any losses of power signals and other user- defined software events. See Section 3.5 for details.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) when ON (half-duplex when OFF). The blinking ACT LED indicates receiving Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) except they have the capability of providing power on each port to power up the PD devices, per the IEEE802.3af PoE standard. The power-pass-through PoE modules are dependent upon the -48VDC input power to supply the PD power for these RJ-45 (10/100) ports.
SFP Gigabit (1000Mbps) port modules The Gigabit port options for the modular slot come in a few different configurations of Fiber SFP’s or RJ-45’s. The Magnum 6KQ offers only SFPs (Small Form Pluggable) for Gigabit speed. There are multiple choices of SFP Gigabit transceiver types to combine with RJ-45’s for the modular slot.
2.2.9 Managed Network Software (MNS-6K ) for Magnum 6KQ-Series Magnum 6KQ’s come with Rel3.6 licensed MNS-6K software, which allows the user to configure the Magnum 6KQ as a Managed Switch and implements security features and other software enabled features.
Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KQ Switches provide unicast non-blocking (all ports can run at full speed at once) performance with standard Managed Network Software (MNS-6K) included. They are typically used in LAN traffic centers with up to 12 100Mb +2 Gigabit ports for backbone connections, where managed network services are desired.
They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit (1000Mb) ports, with industry-standard LAN management software. Magnum 6KQ Switches are easily used in a variety of applications including client/server computing, secure VLAN- performance upgrades to departmental networks, and stream traffic for VOIP and audio/video applications.
Page 24
The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KQ Switch. A main NT-server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port.
Page 25
Ethernet units. The entire spread network will be manageable to provide easy, detectable, uninterrupted support through a viewable SNMP monitor. The Magnum 6KQ Managed Field Switch equipped with a mix of copper and fiber ports provides an economical and seamless solution to many requirements. The...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Example 3. In another application in an industrial environment, a 12 port Nebs compliant, -24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV. The switch must be SNMP enabled and managed to easily monitor the whole setup.
For DC power input data, see Appendix B. For Dual Source, see Appendix C The rugged metal case of the Magnum 6KQ will normally protect it from accidental damage in a lab or workplace setting. Maintain an open view of the front to visually monitor the status LEDs.
3.2.4 Connecting Twisted Pair (CAT3, CAT5, Unshielded or Shielded) The RJ-45 ports of the Magnum 6KQ can be connected to the following two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
& with RJ-45 ports used as indicated here. 3.2.5 Connecting Twisted Pair (CAT5e or better, Unshielded or Shielded) The RJ-45 Gigabit ports of the Magnum 6KQ can be connected to the media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable.
Due to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice for various applications. The small-chassis Magnum 6KQ is designed for industry- standard Gb-SFPs and Gb-SFPCU (copper) for user selection of the SFP gigabit media type as desired.
Page 31
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The various SFPs transceivers supported by GarrettCom 6KQs D slot are- Module Model# Gigabit Gb Modules, fixed ports--SFP 6KQ-2GSFP 2 SFP 6KQ-2GCU 2 CU 6KQ-2GSFPCU 1SFP, 1CU 6KQ-1GSFP 1 SFP...
It is available with optional DIN-Rail brackets to mount it securely in a metal factory floor enclosure, maintained vertically for proper convection cooling of the unit. The Magnum 6KQ requires one DIN-Rail mounting clip or latch for secure mounting. These may be ordered as Model # DIN-RAIL-6KQ. See a 6KQ viewed from the side, at the left, with model DIN-RAIL-6KQ in place on the unit.
6KQ can be moved up and out, free of the DIN-Rail mounting. The picture in Section 3.3 shows vertical mounting of Magnum 6KQ as it about to be mounted on a DIN-Rail track for proper convection cooling of the unit. Note that there is air space in the rear, as the 6KQ unit is held out from the rear of the panel by the mounting brackets.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) air circulation and cooling of the rear part of the case. For best cooling of the 6KQ, attach the metal brackets to metal (rather than wood or plastic). Attaching to metal helps conduct heat away from the 6KQ through the metal brackets and into the metal support structure.
See the Appendices of this manual for more details. Use an RFQ for other variations. 3.5 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, standard on Magnum 6KQ’s, provides two Form C Normally Closed (NC) contacts to which the user can attach two sets of status monitoring wires at the green terminal block.
(04/07) The Alarm Contacts are on the front left area (next to the DC power source) of the Magnum 6KQ unit and are green in color as shown in the picture. 6KQ Port Module (6KPM) Installation Magnum 6KQ Switches are normally received from the factory with all required 6K Port Modules installed.
Switching Functionality A Magnum 6KQ provides switched connectivity at Ethernet wire-speed among all of its ports. The Magnum 6KQ supports10/100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance. All ports can communicate to all other ports in a Magnum 6KQ, but local traffic on a port will not consume any of the bandwidth on any other port.
Address Learning All Magnum 6KQ units have address table capacities of 4K node addresses suitable for use in larger networks. They are self-learning, so as nodes are added, removed or moved from one segment to another, the 6KQ Switch automatically keeps up with node locations.
Page 39
When Magnum 6KQ RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) account for all devices and cable lengths within that domain. For Magnum 6KQ Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT. Flow-control, IEEE 802.3x standard Magnum 6KQ Switches incorporate a flow-control mechanism for Full- Duplex mode.
Page 41
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The following data has been collected from component manufacturer’s (Agilent’s and Lucent’s) web sites and catalogs to provide guidance to network designers and installers. Fiber Speed, Std. Wave Cable X’mitr R’cvr...
An important feature of the Magnum 6KQ is the use of Port Modules for flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first four ports (1,2,3 & 4) of the Magnum 6KQ Switches are fixed RJ-45 copper ports with dual-speed 10/100Mbps auto-negotiating capability. Additionally the...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Each 6KQ Port Module (PM) is individually described in the following sections. For the “6KF-series” fiber modules in slot C, the operational description is the same as the corresponding fiber modules configured in slots B and D described below.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Switch, the fiber port supports fiber optic cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-duplex and half-duplex. Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and an FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 5.2.4 6KQ3-RJMSC “COMBO” 2@ 10/100Mbps RJ-45 Ports and 1@100Mbps Multi-mode FX-SC-type, “snap-in” connector The Magnum 6KQ3-RJMSC is also a Combo module equipped with 2 dual speed copper ports and 1 Multi-mode SC-type connector.
The MT-RJ’s small compact size connector and ease of connection make it a good choice for 100Mbps “fiber-to-the-desktop” Ethernet connectivity. When installed in a Magnum 6KQ Switch, it supports fiber optic cable distances up the IEEE- standard 100Mbps distance limits, i.e., typically 2km at full-duplex or half-duplex.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 6KQ Switch, it supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-duplex. The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of “future-proof”...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Four-port RJ-45 connector, and offers 10/100 full / half-duplex auto-negotiating capability on each port. The RJ-45 connector is shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and shielded twisted pair (STP) cable connections.
The ports will still operate properly for data traffic. 5.2.11 SFPs, Gigabit (1000Mbps) port modules The Magnum 6KQ offers a Gigabit option with multiple choices of copper 10/100/1000Mbps or Gigabit SFP Fiber modules for the modular slot. While up to two Gigabit modules 6KQ-2GSFPCU 6KQ-2GSFPCU (maxm.) can be...
However, if you are unsure of the procedures described in this section or if the Magnum 6KQ Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact GarrettCom Customer Support.
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) When Calling for Assistance Please be prepared to provide the following information. A complete description of the problem, including the following points: a. The nature and duration of the problem;...
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available.
B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES Magnum 6KQ Switches are easily installed in a variety of applications where - 48VDC, 24, or 125VDC power is used as the primary power source. The DC power configuration capability provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record.
Page 54
125VDC leads) to the DC power terminal block on the Magnum 6KQ Switch. The DC terminal block on the Magnum 6KQ Managed Switch is located on the left front of the unit and is equipped with four (4) screw-down lead posts. The power terminals are identified as positive (+) and negative (-), and they are electrically floating inside the unit so that either may be grounded by the user if desired.
4 inches apart, with the first one located within 6 inches of the terminal block. B5.0 OPERATION Operation of Magnum 6KQ Switches with the optional -48VDC, 12VDC, 24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models. B6.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting...
Page 56
Magnum 6KQ -48VDC, 12VDC, 24VDC, 125VDC and 250VDC models with this Dual-Source option are identical to those listed in the Magnum 6KQ Field Switches Installation and User Guide, including Appendix B “Internal DC Power Supply Option”...
Page 57
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Figure C5.0: DC Dual-Source, wiring connections with Dual-Source option. C5.0 INSTALLATION This section describes the proper connection of the -48VDC, 12VDC, 24VDC, 125VDC and 250VDC dual source leads to the power terminal block on the Magnum...
Page 58
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) C6.0 ORDERING INFORMATION FOR DUAL SOURCE POWER To order the optional Dual-Source power supply factory installed, add “Dual- Src-xxxV” as a separate line item following the product model. Example: Magnum 6KQ-48VDC...