14.7 External sensor set-up (where fitted)
When using an outdoor sensor, the microprocessor-
controlled PCB will select the most suitable flow
temperature, taking into account the external temperature
and the type of system. The microprocessor is capable of
doing this because it is possible to establish a link between
the external temperature and the flow temperature of the
Central Heating system water. This link translates into a
"thermal curve".
The type of curve should be chosen in correspondence with
the planned temperature of the system and the nature of the
heat loss present in the building.
To set up the external sensor, proceed as follows;
1. Access the settings menu by pressing the
buttons together for five seconds;
2. Press the
button 5 times to access Menu 6;
3. Press the
button, the 3rd and 4th digits will flash;
4. Press the
or
buttons to change from 1 (sensor not
fitted ) to 0 (sensor fitted) and press the
to select the change;
5. Select the thermal curve required from Table D;
6. Press the
or
buttons to change to Menu 6.2;
7. To adjust the thermal curve, press the
and 4th digits will begin to flash;
8. Press the
or
buttons to select the parameter that
best meets your temperature requirement shown in Table
D (opposite);
9. Once the correct parameter has been set, press the
button again to confirm the selection.

14.8 Adjusting the parallel shift

In the event that the thermal curve set is giving too high or
too low a temperature, there are two options, you can either
alter the thermal curve as described in Section 14.7 or adjust
the parallel shift of the curve.
To adjust the parallel shift, proceed as follows:
1. Access the settings menu by pressing the
buttons together for five seconds;
2. Press the
button 5 times to access Menu 6;
3. Press the
or
buttons to access Menu 6.3;
4. Press the
button, the 3rd and 4th digits will flash;
5. Press the
or
buttons to adjust the parallel shift up
and down in steps of 1 between 0 and 20 (see Table E).

14.9 Completion

For the Republic of Ireland it is necessary to complete a
"Declaration of Conformity" to indicate compliance to I.S.813.
An example of this is given in the current edition of I.S.813.
In addition it is necessary to complete the
Commissioning Checklist in Section 24 of this manual (Page
60).
and
button again
T
D
ABLE
C
ONVECTOR
S
R
TEEL
O
VERSIZED
U
NDERFLOOR
button, the 3rd
* W
HERE
SELECTED
CONNECTED TO THE MAIN
26)
IN ORDER TO PROTECT THE UNDERFLOOR HEATING SYSTEM
and
T
E
ABLE
R
-
C
ADIATOR
-
C
ADIATOR
S
R
-
C
TEEL
ADIATOR
H
-
C
EATING
C
0.3
0.5 (
URVE
OR
UNDERFLOOR HEATING
,
A SUITABLE SYSTEM SAFETY THERMOSTAT MUST BE
PCB
TERMINAL
2.5
3
URVES
TO
1.5
2
URVES
TO
1
1.2
URVES
TO
0.3
0.5*
URVES
TO
)
ARE
14 (
Fig. 32, page
SEE
.
35