Ariston C Operating Instructions Manual page 45

Type c boilers
Table of Contents

Advertisement

17. Adjustments and Setting
CH anti cycling delay setting :
If you would like to change the setting of CH anti cycling delay to 3 mins, please proceed as follows:
(
: the factory setting is 2 min 30 seconds and the following explanation refers to Menu 4 Section 8)
NOTE
1
Switch to installer mode, press the
and
keys for 5 seconds, the
display shows :10=0 if there is no
default in the default register.
2
Press the menu key
to gain access to menu 4, the display
shows : 40=0 or 40=1
3
Change to section 8 (CH anti-cycling
delay), press the
the display shows :48=2.5 (factory
setting 2 min 30 secs)
4 = menu 4
8 = section 8
2.5 = 2.5 min (2 min 30 seconds)
4
Press the setting key
3rd and 4th digits flash together.
Then press the
the CH anti-cycling delay, the display
shows:
48=3.0 press the setting key
confirm the value. The display stops
flashing.
To exit from setting mode, leave the
boiler for approx. 1 minute the boiler
will automatically switch back to the
user mode.
After programming please close the
door P (Fig. 46)
1
2
three times
3
key eight times,
4
once, the
key to change
to
(continued)
5 "
Display
x 3
or
x 8
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System a 24 mffiSystem a 30 mffi