Room Thermostat Connection; Outdoor Sensor Connection - Ariston CLAS HE Series Installation And Servicing Instruction

Gas fired condensing wall hung combination boilers
Hide thumbs Also See for CLAS HE Series:
Table of Contents

Advertisement

installation

Room thermostat connection

Introduce the thermostat wire
-
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the room thermostat one at a time.
- Connect the wires to the terminals as indicated in the figure
below, removing the link
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed
- Close the flap again, then replace the control panel cover and
the front casing.
Connector TA on PCB
(low voltage switching)

Outdoor sensor connection

Introduce the outdoor sensor wires
-
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the outdoor sensor one at a time.
- Connect the wires to the terminals as indicated in the figure
below;
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed;
- Close the flap again, then replace the control panel cover and
the front casing.
- Refer to page 39 for setting the parameters when using the
outdoor sensor.
Outdoor Sensor
Connector SE on PCB
N
:
w
ote
heN
coNNectiNg
the
240V
Not
ruN
cables
(
which
are
low
Voltage
preVeNt
iNduced
Voltage
4
,
boiler
to
exterNal
coNtrols
do
aNd
cables
for
switchiNg
circuits
)
,
together
use
seperate
cables
oN
the
low
Voltage
circuits
TA1
to
.
SE