To adjust the boiler temperature:
Turn the boiler thermostat knob
clockwise to the required setting. The
optimum boiler thermostat setting
depends upon type of system,
external
controls
requirements. Your Installer will be
able to advise you on this matter.
Clip the lamp box back into
9
position and replace the fire
hearth by guiding the hearth location
pins into the holes provided on the
facia. Push the hearth at the bottom
to secure the clips.
Location Pin
10
TO LIGHT THE FIRE - Push in
the control knob then turn anti-
clockwise to the ignition/pilot position
and
hold.
Sparking
commence and the pilot will ignite.
When lit, the pilot is visible at the front
centre of the coalbed. Continue to
hold the control knob in position for a
further 15 seconds before releasing.
The pilot should stay alight.
NOTE:- If the pilot fails to remain
alight or is extinguished at any time,
wait at least two minutes, then repeat
step 10. Once the pilot is alight it may
be left on permanently.
11
TO
ADJUST
OUTPUT: Push in the control
knob and turn to one of the available
positions, as shown below.
Position
- Off
Position
- Ignition/Pilot
Position 1
- Low
Position 2
- Medium
Position 3
- Medium/High
Position 4
- High
NOTE:- When your Bermuda is first used
it is possible that certain smells may be
emitted. These smells will quickly clear
with use. As the fire is used more and
more, the bright finished metal around the
coalbed will begin to darken. This is
perfectly normal and will enhance the
realism of the coal and flame effect.
12
TO TURN THE FIRE OFF
Push in the control knob and
turn clockwise to the OFF position.
The pilot light can be left on by
stopping at the
position but the
fire is not completely off until the
control knob is turned to position
and
your
will
Hearth
Handle
Rotate Lamp Box
Forward Using The
THE
FIRE
Handles Provided
Plug & Socket
.
Light Switch
Pilot Burner
Match
View of Boiler Controls
when Lamp Box is
rotated forward
(Manual Controls Boiler
401, 552)
Location Pin
page 5

LIGHTING EFFECT

The light effect is operated by a
switch below the control knob and
may be used with or without the fire
being on.
IGNITION WITH A MATCH
If the electricity supply fails, the fire
may be lit with a match. Remove the
fire hearth by grasping it on either
side at the bottom, and pulling
towards you. This will release the
clips and allow the hearth to be lifted
away by drawing it forward.
The pilot burner is now visible at the
front centre of the coalbed.
Push in the control knob, then turn
anti-clockwise to the ignition/pilot
position
and hold. Light the pilot
with a match.
Continue to hold the control knob in
for a further 15 seconds, before
releasing. The pilot should stay alight.
Replace the fire hearth by guiding the
hearth location pins into the holes
provided on the facia and pushing the
hearth at the bottom to secure the
clips.

BULB REPLACEMENT

The fire should only be fitted with 15
watt amber pygmy bulbs. The bulbs
can
be
obtained
from
supermarkets.
Turn the fire control knob to the OFF
position
, switch the bulbs off and
allow to cool.
Remove the fire hearth by grasping it
on either side at the bottom, and
pulling towards you. This will release
the clips and allow the hearth to be
lifted away by drawing it forward.
The lamp box, which is clipped at the
top and hinged at the bottom, can
now be rotated forward to gain
access the plug supplying electricity
to the fire. Use the handles provided.
Isolate the electricity supply to the fire
by disconnecting the plug from the
socket (as shown).
Replace the bulbs as necessary and
re-connect the plug and socket.
Clip the lamp box back into position
and replace the fire hearth by guiding
the hearth location pins into the holes
provided on the facia. Push the
hearth at the bottom to secure the
clips.