DISHWASHERS WITH MANUAL CONTROL SYSTEM:
-
Valves A, B and C may be open or closed, and are connected to the respective dosing chambers
(a, b and c); chamber d is independent (not adjustable).
-
If the valve is open, the corresponding dosing chamber is filled during the water fill cycle.
-
If the valve is closed, the corresponding dosing chamber remains empty.
-
When the regeneration solenoid valve is energized, the chambers are completely drained of water.
DISHWASHERS WITH ELECTRONIC CONTROL SYSTEM:
-
Valves A, B and C remain open, thus the corresponding dosing chambers (a, b and c) are always filled
with water, chamber (d), too, which is independent, is filled.
-
When the regeneration solenoid valve is energized, all the chambers are completely drained of water.
REGENERATION TANK - FUNCTIONAL DIAGRAM
- 23 -