WATER HEATING Time-out
-
The maximum duration of the water heating phase
is 45 minutes, irrespective of the temperature
for the selected cycle.
-
The time-out counter starts at the beginning
of each water heating phase (i.e. when the
heating element switches on), and ends when
the correct temperature is reached.
-
If the time required for the water to reach
the correct temperature is more than 45 minutes,
an alarm condition is generated.
-
During the final drying phase (after the last
hot rinse has been drained), this safety time-out
is no longer operative.
PRESSURE SWITCH "EMPTY" Time-out
(end of drain phase)
-
At the end of each drain phase, it is checked
that the pressure switch is in the "empty"
condition (1 - 2).
-
If the pressure switch is in the "full" condition
(1 - 3) at the end of the drain phase,
an alarm condition is generated.
Appliance:
When the door is opened:
DIGIT window:
LEDs:
Appliance:
When the door is opened:
DIGIT window:
LEDs:
- 43 -
SITUATION
STOPPED
H (flashing)
OFF
SITUATION
STOPPED
P (flashing)
OFF