Expansion Vessel Precharge Pressure; Spare Parts - Heatrae Sadia Multipoint 30 Installation And User Instructions Manual

30 and 50 litre unvented water heaters
Hide thumbs Also See for Multipoint 30:
Table of Contents

Advertisement

Reducing Valve and remove. The strainer will be removed with the
cap. Wash any particulate matter from the strainer under clean
running water. Replace the cap assembly ensuring the sealing ring
is correctly fitted. Do not use any other type of sealant. Close hot
tap, open mains stop cock and check for leaks.
10.0 MAINTENANCE -

EXPANSION VESSEL PRECHARGE PRESSURE

The Expansion Vessel should have a precharge pressure of 3.5 bar (51
p.s.i.). This can reduce over time and eventually require re-charging. To
do this:
10.1
Turn off water supply to the unit; open a hot tap to relieve system
pressure.
10.2
Remove dust cap from top of Expansion Vessel
10.3
Check pre-charge pressure using a tyre pressure gauge. If the
pressure is lower than 3.5 bar (51 p.s.i.) it should be recharged
using a tyre pump (Schraeder Valve type). DO NOT OVER
CHARGE.
10.4
Re-check pressure and when correct replace dust cap.
10.5
Turn on mains water supply and close hot tap.

11.0 SPARE PARTS

The following comprehensive list of spare parts is available for your
Multipoint water heater. Please refer to the Rating Label on the side of
your heater before ordering to ensure the correct spare part is obtained.
DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY
HEATRAE SADIA - THIS WILL INVALIDATE YOUR GUARANTEE AND
MAY RENDER THE INSTALLATION DANGEROUS.
DESCRIPTION
Element plate assembly - 30/50 litre 3kW ............. 95 606 926
Element plate assembly - 30/50 litre 1kW ............. 95 606 925
Thermostat ........................................................... 95 612 667
Thermal cut-out .................................................... 95 612 666
Indicator light ....................................................... 95 607 995
Element plate gasket ............................................ 95 611 811
Pressure (expansion) Relief Valve ........................ 95 607 986
Temperature/Pressure Relief Valve ....................... 95 905 045
Check Valve .......................................................... 95 607 987
Expansion Vessel ................................................. 95 607 988
Pressure Reducing Valve ..................................... 95 607 989
Terminal cover c/w thermostat knob .................... 95 614 184
CODE NO.
9