Installation - Plumbing - Heatrae Sadia Multipoint 30 Installation And User Instructions Manual

30 and 50 litre unvented water heaters
Hide thumbs Also See for Multipoint 30:
Table of Contents

Advertisement

Diagram 3 Bracket and Levelling Feet Positions

4.0 INSTALLATION - PLUMBING

4.1 Refer to the section IMPORTANT INSTALLATION POINTS. Plumb
in the valves in the sequence shown in Diagram 1. Ensure the valves
are installed in the correct orientation by reference to the direction of
flow arrows marked on them. The Expansion Vessel should be
supported by its own wall bracket (supplied), do not rely on the
pipework alone to support it.
4.2 The water connections to the unit are 15mm diameter copper tubes
suitable for compression fittings. Do not use solder joints as this will
damage the heater and may prevent servicing under warranty.
4.3 The INLET is marked BLUE, the OUTLET is marked RED. Several hot
outlets via conventional taps can be served, however, individual site
demands should be considered when choosing capacity and the
number of outlets to be served.
4.4 It is recommended that a WRAS Listed isolating valve is fitted on the
cold water supply to the heater.
4.5 A drain cock must be fitted below the heater in the inlet pipework. It
must be sited between the heater and the Check Valve (see Diagram
1).
4.6 Plumbers Paste must not be used as it can impair the operation of the
valves.
5