ZISE##-TFM113GB
Setting (Continued)
Function selection mode
In measurement mode, press the
button for 2 seconds or longer to
display [F 0]. Select to display the function setting to be changed, [F
Press the
button for 2 seconds or longer in function selection mode to
return to measurement mode.
Measurement mode
Press the
button
for 2s or longer.
Function selection mode
Setting functions
*: Some functions are not available depending on part number. All functions are
displayed with
[F
]
and followed with function description. If a function is not
available for specified type, the function is displayed as [---].
To set each function in detail, refer to the operation manual.
Other Functions
•Peak/Bottom hold value indication
•Zero clear
•Key lock
To set each function in detail, refer to the operation manual.
Maintenance
How to reset the product for power cut or forcible de-energizing
The setting of the product will be retained as it was before a power cut or
de-energizing.
The output condition is also basically recovered to that before a power
cut or de-energizing, but may change depending on the operating
environment. Therefore, check the safety of the whole system before
operating the product.
If the system is using accurate control, wait until the pressure switch has
warmed up (approximately 10 minutes)
Error Indication Function
This function is to display error location and content when a problem or
an error occurs.
Error
Troubleshooting
Error Name
Error Nature
Display
Method
Turn the power off and
remove the output
Over
A load current of switch
factor for the over
current
output is 80 mA or
current.
Error
more.
Then turn the power
on.
During zero clear
operation, pressure
over
7%F.S.
±
(
3.5%F.S.for
Perform zero clear
±
compound pressure) is
operation again after
Zero-clear
applied. After 1 s, the
restoring the applied
Error
mode will reset to the
pressure to an
measurement mode.
atmospheric pressure
1%F.S. of the zero
condition.
±
clear range varies
with individual product
differences.
Error Indication Function (Continued)
Error
Error Name
Error type
Display
].
Pressure has exceeded
the upper limit of the set
pressure range.
Reset applied pressure
Pressurizing
to a level within the set
Error
pressure range.
Pressure has exceeded
the lower limit of the set
pressure range.
Turn the power off and
turn it on again.
Displayed in the case of
System
If resetting fails, an
an internal
Error
investigation by
data error.
SMC CORPORATION
will be required.
If the error can not be reset after the above measures are taken, then
please contact SMC.
Troubleshooting
Refer to the operation manual for this product.
Specification
Refer to the operation manual and catalogue for this product.
Outline with Dimensions (in mm)
Refer to the operation manual and catalogue for this product.
Troubleshooting
Method
Contact
AUSTRIA
(43) 2262 62280
NETHERLANDS
(31) 20 531 8888
BELGIUM
(32) 3 355 1464
NORWAY
(47) 67 12 90 20
CZECH REP.
(420) 541 424 611
POLAND
(48) 22 211 9600
DENMARK
(45) 7025 2900
PORTUGAL
(351) 21 471 1880
FINLAND
(358) 207 513513
SLOVAKIA
(421) 2 444 56725
FRANCE
(33) 1 6476 1000
SLOVENIA
(386) 73 885 412
GERMANY
(49) 6103 4020
SPAIN
(34) 945 184 100
GREECE
(30) 210 271 7265
SWEDEN
(46) 8 603 1200
HUNGARY
(36) 23 511 390
SWITZERLAND
(41) 52 396 3131
IRELAND
(353) 1 403 9000
UNITED KINGDOM
(44) 1908 563888
ITALY
(39) 02 92711
URL http://www.smcworld.com (Global) http://www.smceu.com (Europe)
Specifications are subject to change without prior notice from the manufacturer.
©2008 SMC Corporation All Rights Reserved.
Need help?
Do you have a question about the ZSE10 Series and is the answer not in the manual?
Questions and answers