A) Materials Provided

The inverter/charger is provided with an installation kit containing the following:
(2 ea.) Cable clamps
(1 ea.) Warning label for AC distribution panel
(1 ea.) Installation/Operation Manual
(1 ea.) Customer satisfaction/warranty card
If items any are missing, please contact the factory. Upon completion of the installation,
please fill out the warranty card and return it to the factory. (Be sure to include the serial
number of the unit, located on the top of the housing.)

B) Location

The inverter/charger should be located as close to the batteries as possible, ideally no more
than about 4-6 feet. The maximum allowable distance is 20 feet. Do not mount the unit
directly over the batteries as battery fumes may cause excessive corrosion. WARNING: The
inverter/charger is not ignition protected so it must not be located in an area containing gaso-
line engines or the like, nor in any other area where ignition protected equipment is required.
The area should be well ventilated and free from moisture, exhaust manifolds and battery
fumes.
Do not locate the unit where water, spray or condensation can occur, as this will shorten its
life. It should not be located where there is a possibility of dust or debris being drawn into
the unit through the fan. A minimum of 2" clearance around the unit is recommended for
proper cooling.
If the inverter/charger is located in an extreme heat area, such as an unventilated engine
room, and maximum operating temperature is exceeded, an automatic thermal protection
circuit will shut the unit completely off. It will automatically return to service when it has
cooled sufficiently, however this thermal cycling will shorten the life of the inverter/charger,
so if this condition occurs repeatedly, it should be relocated. For optimum performance and
longer life the unit should not be located in an area of high temperature.

C) Mounting

The inverter/charger may be mounted on either a horizontal or vertical surface; performance
will be unaffected by its orientation, however, per UL safety recommendations, when
mounted vertically the front panel controls should be facing downward. It may be mounted
on either a metal or non-metal surface. Four 1/4" screws (wood or machine screws, depend-
ing on mounting surface) with washers are required to secure the unit to the mounting
surface.
IMPORTANT: Although the inverter/charger is constructed of materials and in a manner
which makes it resistive to the corrosive effects of the marine environment the unit is not
waterproof. Do not mount the charger where there is a possibility of water entering the unit.
Evidence of water entry into the charger will void the warranty.
4
U.S.A. HEADQUARTERS
P.O. Box 1306, Newport Beach, CA 92663
Phone: 714-751-0488 Fax: 714-957-1621
E-Mail: sales@newmarpower.com
www.newmarpower.com
EURO WAREHOUSE
Phone:+31-35-603-2494 Fax:+31-35-603-2149
E-Mail: newmareuro@newmarpower.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Guided wave 12-1799icGuided wave 24-1300ic

Table of Contents