ENGLISH

PRESET

15
1. Preset mode
q The preset mode is available when PRESET button is pushed for more than 1 sec while DN-D9000 is in
Cue, pause or no disc mode.
w Turn the PARAMETERS knob to select the preset item.
e After selecting an item, push the PARAMETERS knob to select the preset data.
r To change other Preset items, repeat these steps.
t Push the PRESET, CUE or PLAY/PAUSE button to exit from the Preset mode.
2. Preset items and data
The "*" mark next to the data indicates the default value.
(1)
AUTO CUE: Auto Cue level search on/off.
ON* / OFF
(2)
PITCH RANGE: Select the playing pitch range when the power is turned on.
±4 / ±10* /±16 / ±24%
(3)
ALPHA-TRACK OUTPUT: Alpha-Track playback output destination.
Main out* / Monitor out
(4)
AUTO CLOSE: Time for automatically closing disc holder.
OFF / 10 / 30* / 60 seconds
(5)
EOM: Track end message start time.
OFF / 10* / 15 / 20 / 30 / 60 / 90 seconds
(6)
Alpha-Track FADER START: Select the Alpha-Track fader Start ON/OFF.
ON / OFF*
(7)
FADER: Select 2-line type (Cue and Play) or 1 line type (Play and Pause).
PLAY/CUE* / PLAY/PAUSE
(8)
POWER ON PLAY: Playback starts when the power is turned on if a disc is loaded.
ON / OFF*
(9)
A3/4 MODE: Select the A3 and A4 button operating modes when the power is turned on.
Sampler* / 4H/S / Alpha-Track H/S
(10) SINGLE/CONTINUOUS: Select the play mode when the power is turned on.
SINGLE* / CONTINUOUS
(11) ELAPSED/REMAIN: Select the time mode when the power is turned on.
ELAPSED* / REMAIN
(12) PROGRAM ALL CLEAR: Clear all program play data in the non-volatile memory.
NOTE: This Preset item can be only performed in CD1 (left side) of the remote controller.
q To clear the program, push the PARAMETERS knob and select "YES".
• "Clear OK?" flashes on the character display.
w Push the PARAMETERS knob again and select "OK" to execute clearing the program.
"Prog. Clear" is displayed on the character display while data clearing.
e Once clearing is completed, "Complete!" is displayed.
(13) MEMO ALL CLEAR: Clear all MEMO data in the non-volatile memory.
NOTE: This Preset item can be only performed in CD1 (left side) of the remote controller.
q To clear all MEMO data, push the PARAMETERS knob and select "YES".
• "Clear OK?" flashes on the character display.
w Push the PARAMETERS knob again and select "OK" to execute clearing all MEMO data.
• "Memo Clear" is displayed on the character display while clearing.
e Once clearing is completed, "Complete!" is displayed.
(14) MEMO ALL COPY: Copy all MEMO data from the master unit of DN-D9000 (or DN-2600F) to the slave
unit of DN-D9000 when both unit are connected by the specified Cross Cable. (See
diagram for the cable.)
NOTE: This Preset item can be only performed in CD1 (left side) of the remote controller.
Also, be sure that both disc trays are open, or both have no discs inside.
22
A cross cable used:
Lch
DN-D9000
Rch
GND
(Sleeve)
• Using the cross cable, connect the X-EFFECT terminals between two DN-D9000 units or
between one DN-2600F and one DN-D9000 unit.
• If a DN-2600F is the master unit, take the procedures below in the Preset mode of the DN-2600F
beforehand. (For details, refer to the DN-2600F's operating instructions.)
Set the "Copy Master" for the Preset item (14).
Then, step to the q below on the slave unit of DN-D9000.
-TRACK HOT START
-TRACK PLAY
RVS
SAMP1
SAMP2
SAMPLER
B
EXIT/RELOOP
PARAMETERS
TRACK
STOP
PUSH
ON/OFF
FLIP
A 3
A 4
B
EXIT/
CUE
OPEN/
RELOOP
CLOSE
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
PITCH BEND
FLIP
A 1
A 2
B
EXIT/
RELOOP
CLR
A1 A2
4 HOT START
PITCH/VOL
SPLICE
RANGE
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
DUMP
MEMO
PROG
RVS
0%
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
REMOTE CONTROLLER RC-D90
DN-D9000-1
OPEN/CLOSE
1
POWER
ON
-TRACK HOT START
-TRACK PLAY
SAMPLER
PARAMETERS
TRACK
RVS
SAMP1
SAMP2
B
EXIT/RELOOP
STOP
PUSH
ON/OFF
EXIT/
CUE
OPEN/
FLIP
A 3
A 4
B
RELOOP
CLOSE
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
PITCH BEND
EXIT/
FLIP
A 1
A 2
B
RELOOP
CLR
A1 A2
4 HOT START
PITCH/VOL
SPLICE
RANGE
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
MEMO
DUMP
PROG
RVS
0%
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
REMOTE CONTROLLER RC-D90
DN-D9000-2
OPEN/CLOSE
1
POWER
ON
• Perform the copying operation as below on the slave unit of DN-D9000.
q To start copying, push the PARAMETERS knob and select "YES". Now "Copy OK?" messages
flashes on the character display.
w Push the PARAMETERS knob again to confirm. Now "Start OK?" is displayed.
NOTE: If a DN-2600F is the master unit, take the procedures below in the Preset mode of the
DN-2600F here.
In the Preset item (15), first start copying on the DN-2600F. Then, step to e below on the
slave unit of DN-D9000.
e Push the PARAMETERS knob once again, and the unit starts copying when the MEMO data are
received from the master unit. Now "Copying" is displayed.
• If the master unit and the slave unit are not connected properly or the DN-2600F is not
prepared to start sending data, "Not Connect" is displayed on the character display.
r When copying is completed correctly, "Complete!" is displayed.
• "Copy Error" is displayed on the character display if copying was not completed correctly.
In this case, try the above procedure again.
• The copied MEMO data are added to the highest number area of the slave DN-D9000 unit.
(15) PRESET CLEAR: Set all the preset data back to the factory defaults.
q To clear the PRESET data, push the PARAMETERS.
"Initial OK?" flashes on the character display.
w Push the PARAMETERS knob again and select "OK" to start clear the preset data.
"Preset Int" is displayed on the character display while data clearing.
e Once clearing is completed, "Complete!" is displayed.
(Tip)
Lch
(Tip)
DN-D9000
(Ring)
(Ring)
Rch
GND
(Sleeve)
-TRACK HOT START
-TRACK PLAY
RVS
SAMP1
SAMP2
SAMPLER
B
EXIT/RELOOP
PARAMETERS
TRACK
STOP
PUSH
ON/OFF
FLIP
A 3
A 4
B
EXIT/
CUE
OPEN/
RELOOP
CLOSE
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
PITCH BEND
FLIP
A 1
A 2
B
EXIT/
RELOOP
CLR
A1 A2
4 HOT START
PITCH/VOL
SPLICE
RANGE
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
DUMP
MEMO
PROG
RVS
0%
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
OPEN/CLOSE
2
X-EFEECT jack
OFF
-TRACK HOT START
-TRACK PLAY
SAMPLER
PARAMETERS
TRACK
RVS
SAMP1
SAMP2
B
EXIT/RELOOP
STOP
PUSH
ON/OFF
EXIT/
CUE
OPEN/
FLIP
A 3
A 4
B
RELOOP
CLOSE
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
PITCH BEND
EXIT/
FLIP
A 1
A 2
B
RELOOP
CLR
A1 A2
4 HOT START
PITCH/VOL
SPLICE
RANGE
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
MEMO
DUMP
PROG
RVS
0%
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
OPEN/CLOSE
2
X-EFEECT jack
OFF

Advertisement

Table of Contents
loading

Table of Contents