Denon DN-D9000 Operating Instructions Manual page 17

Double cd player
Hide thumbs Also See for DN-D9000:
Table of Contents

Advertisement

A3/A4 FOR SAMPLER, 4 HOT START, ALPHA-TRACK HOT
11
START
The buttons of A3, A4 and corresponding FLIP, B and EXIT/RELOOP are used for Sampler, 4 Hot Start and Alpha-
Track Hot Start functions.
-TRACK HOT START
SAMPLER
RVS
SAMP1
SAMP2
B
EXIT/RELOOP
EXIT/
FLIP
A 3
A 4
B
RELOOP
CLR
A3 A4 CUE
EXIT/
FLIP
A 1
A 2
B
RELOOP
CLR
A1 A2
4 HOT START
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
MEMO
DUMP
PROG
RVS
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
A3/A4 mode
Select A3/A4 Mode
The A3 and A4 buttons can be used for one of
the three modes described below.
• Sampler mode
• 4 Hot Start mode (A1, A2, A3 and A4)
• Alpha-Track Hot Start mode
q When the
A 3/4
A 3/4 button is
pushed, the operating mode
can be selected with the
PITCH/VOL
PARAMETERS knob.
The PARAMETERS LED flashes and the
A3/A4 mode is displayed on the character
display.
w Turn the PARAMETERS knob and select the
1
-1
A3/A4 button mode, then push the
PARAMETERS knob to set.
PARAMETERS
TRACK
PARAMETERS
TRACK
PUSH
PUSH
ON/OFF
ON/OFF
q
w
-TRACK PLAY
-TRACK HOT START
SAMPLER
PARAMETERS
TRACK
RVS
SAMP1
SAMP2
STOP
PUSH
ON/OFF
OPEN/
CUE
FLIP
A 3
A 4
CLOSE
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
PITCH BEND
FLIP
A 1
A 2
PITCH/VOL
SPLICE
CLR
A1 A2
RANGE
A3
B
A1
B
TOTAL
REMAIN
ELAPSED
CONT.
m
m
s
MEMO
PROG
0%
CONT./SINGLE
TIME
MEMO
RELAY
TOTAL TIME
PRESET
CUE
STUTTER
PLAY/PAUSE
REMOTE CONTROLLER RC-D90
Sampler mode:
The A3 and A4 buttons lights up in green.
• In Sampler mode, A3 button used for
Sampler1 and A4 buttons are used for
Sampler2.
• The sampled data is stored in the
memory, even when the mode is
changed.
4 Hot Start mode:
The A3 and A4 buttons light up in orange.
• Like the A1 and A2 buttons, the A3 and
A4 buttons are also used for Hot Start,
Stutter and Seamless loop playback.
Then total 4 Hot Start points can be set,
1
one each at buttons A1, A2, A3 and A4.
-2
• The A3 and A4 points set in the 4 Hot
Start mode can be used in Alpha-Track
Hot Start mode as well.
Alpha-Track Hot Start mode:
The A3 and A4 buttons light in green.
• Like the A1 and A2 buttons, the A3 and
A4 buttons are also used for Hot Start,
Stutter and Seamless loop playback.
However, A3 and A4 Hot Start is played
for the Alpha-Track.
• The A3 and A4 points set in the Alpha-
Track Hot Start mode can be used in
the 4 Hot Start mode as well.
q, r, !0
i, !0
B
EXIT/RELOOP
ST
EXIT/
B
C
RELOOP
A
EXIT/
B
RELOOP
PITCH
4 HOT START
A4
B
A2
B
SINGLE
KEY ADJ.
DRAG S.
s
BRAKE
f
ECHO
DUMP
RVS
PROGRAM
PLATTER MODE
RANDOM
ALL OFF
Sampler
TAP
DN-D9000 has four Samplers (two Samplers for each drive) of 15 seconds length. These Samplers are also used
AUTO
in looping playback.
Record in Sampler
q When the SAMP button
(SAMP1 (A3) or SAMP2 (A4))
is pushed in the standby or
playing, the sound from A3 or
A4 point is recorded to
1
Sampler memory up to 15
seconds.
• The SAMP1 or SAMP2 button is flashing
while recording. When the recording is
completed, the button turns off and the
corresponding SAMP B LED lights up.
Setting B point
w When the B button is pushed
during Sampler recording, the
Sampler Loop B point is set
and the loop mode turns on.
• Recording continues for approximately
2
15 seconds without stopping after set B
point.
• If the B point is not set, recording end
point set as B point automatically. Also
EXIT/RELOOP LED light to indicates
Sampler Loop mode is set automatically.
Stop recording
e To stop recording before
recording finish automatically
3
with memory full, push the
STOP (ALPHA-CUE) button.
• The EXIT/RELOOP LED light to indicates
Sampler Loop mode is set automatically.
y, u
w, o
e, t
-TRACK HOT START
-TRACK PLAY
SAMPLER
PARAMETERS
RVS
SAMP1
SAMP2
B
EXIT/RELOOP
STOP
PUSH
ON/OFF
EXIT/
FLIP
A 3
A 4
B
CUE
RELOOP
CLR
A3 A4 CUE
A 3/4
A/B TRIM
PITCH/KEY
EXIT/
FLIP
A 1
A 2
B
RELOOP
CLR
A1 A2
4 HOT START
PITCH/VOL
SPLICE
RANGE
A3
B
A4
B
A1
B
A2
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
DRAG S.
m
s
BRAKE
m
s
f
ECHO
MEMO
DUMP
PROG
RVS
CONT./SINGLE
TIME
MEMO
PROGRAM
PLATTER MODE
RELAY
TOTAL TIME
PRESET
RANDOM
ALL OFF
CUE
TAP
STUTTER
PLAY/PAUSE
AUTO
Play Sampler sound
r Playback of the Sampler
sound starts when the SAMP
A 3
button is pushed after
recording has stopped.
• Sampler playback continues in looping.
With setting B point, playback loop
between A and B point. Without B point
4
setting Sampler loops whole recorded
length (about 15 seconds).
NOTE: It is not possible to play Sampler1
and Sampler2 at the same time.
t To stop the Sampler sound
push STOP (ALPHA-CUE)
B
button.
Select Sampler Loop mode
You can select loop mode for Sampler when
sampler playback stop.
Loop (default):
Sampler playback continues with
looping.
(EXIT/RELOOP LED stays lit)
Exit:
Sampler playback continues over B
5
point up to recording length.
(EXIT/RELOOP LED flashes)
STOP
Single: Sampler playback stops at B point.
CUE
(EXIT/RELOOP LED turned off)
y To select loop mode, push
EXIT/RELOOP button after
recording and before playing.
ENGLISH
-TRACK HOT START
SAMPLER
TRACK
RVS
SAMP1
SAMP2
B
OPEN/
FLIP
A 3
A 4
B
CLOSE
CLR
A3 A4 CUE
PITCH BEND
FLIP
A 1
A 2
B
CLR
A1 A2
A3
B
A1
B
TOTAL
REMAIN
ELAPSED
CONT.
SINGLE
KEY ADJ.
m
s
m
s
f
MEMO
PROG
0%
CONT./SINGLE
TIME
MEMO
PROGRAM
RELAY
TOTAL TIME
PRESET
RANDOM
CUE
STUTTER
PLAY/PAUSE
REMOTE CONTROLLER RC-D90
A 3
STOP
CUE
EXIT/
RELOOP
17

Advertisement

Table of Contents
loading

Table of Contents