AV-32WL1EU
AV-32WL1EI
AV-32WL1EK
Measuring
Item
instrument
Adjustment
Signal
generator
of SUB
COLOUR Ⅱ Ⅱ Ⅱ Ⅱ
Oscilloscope
Remote
control unit
Mg
W
Cy
26
Test point
Adjustment part
10.COLOUR
TP-47B
TP-E(# # # # )
[CRT
SOCKET
PWB ]
PAL COLOUR
( ( ( ( -
- -
- ) ) ) )
(A)
B
0V
( ( ( ( +
+ ) ) ) )
+ +
SECAM COLOUR
[Except for the AV-
32WL1EK]
NTSC COLOUR
NTSC 4.43 COLOUR
No. 51733
Description
[Method of adjustment using measuring instrument]
1. Receive the PAL full field colour bar signal(75% white).
2. Select 2.V/C from the SERVICE MENU.
3. Select 10.COLOUR with the FUNCTION UP/DOWN key.
4. Set the initial setting value of PAL COLOUR with the
FUNCTION LEFT/RIGHT key.
5. Connect the oscilloscope between TP-47B and TP-E
6. Adjust PAL COLOUR and bring the value of (A) in the illustration
-3V
to
(voltage difference between white (w) and blue (B)).
7. Press the OK key and memorize the setting value.
1. Receive the SECAM full field colour bar signal(75% white).
2. Set the initial setting value of SECAM COLOUR with the
FUNCTION LEFT/RIGHT key.
3. Adjust SECAM COLOUR and bring the value of (A) of the
-6V
(W ~ B).
illustration to
4. Press the OK key and memorize the setting value.
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal (full field
colour bar with 75% white) from the EXT terminal.
2. Set the initial setting value of NTSC 3.58 COLOUR with the
FUNCTION LEFT/RIGHT key.
3. Adjust NTSC 3.58 COLOUR and bring the value of (A) of the
-3V
(W ~ B).
illustration to
4. Press the OK key and memorize the setting value.
1. When NTSC 3.58 is set, NTSC 4.43 will be automatically set at
the respective values.