CognitiveTPG A798 Programming Manual page 75

Thermal receipt printer
Hide thumbs Also See for A798:
Table of Contents

Advertisement

Revision C 12/09
An application using DLE (0x10) sequence must send EOT within 100 milliseconds of DLE or the printer will
misinterpret the DLE and execute a clear printer command. Avoid this possibility by using the ID 04 n sequence, which is
handled exactly the same as 10 04 n.
Unlike the A793, that had a dedicated connector and resultant dedicated status reporting for each cash drawer, the A798
has a single connector that shares data reporting from either cash drawer. When either cash drawer is open, an open status
is reported by the printer.
Related information
1 = Transmit printer status
Bit Status Hex Decimal Function
0
Off
00
0
1
On
02
2
2
Off
00
0
On
04
4
3
Off
00
0
On
08
8
4
On
10
16
5
6
7
Off
00
0
2 = Transmit RS-232C Busy Status
Bit Status Hex Decimal Function
0
Off
00
0
1
On
02
2
2
Off
00
0
On
04
4
3
Off
00
0
On
08
8
4
On
10
16
5
Off
00
0
On
20
32
6
Off
00
0
On
40
64
7
Off
00
0
Continued...
Fixed to Off.
Fixed to On.
One or both cash drawers open.
Both cash drawers closed.
Not busy at the RS-232C interface.
Printer is busy at the RS-232C interface.
Fixed to on.
Undefined.
Undefined.
Fixed to off.
Fixed to off.
Fixed to on.
Cover closed.
Cover open.
Paper feed button is not pressed.
Paper feed button is pressed.
Fixed to on.
Printing not stopped due to paper condition.
Printing stopped due to paper condition.
No error condition.
Error condition exists in the printer.
Fixed to off.
A798-PG00001C
Chapter 4: Programming Commands
75

Advertisement

Table of Contents
loading

Table of Contents