Policy Reference Guide
If you do not configure this rule, the user can change the Number of Transactions field to any value.
Minimum requirements
BlackBerry® Enterprise Server version 4.0 SP5
BlackBerry Smart Card Reader software version 1.5
Exceptions
The BlackBerry® Enterprise Server for Novell® GroupWise® does not support this rule.

Maximum PC Bluetooth Traffic Inactivity Timeout IT policy rule

Description
This rule specifies the maximum time (in minutes) of inactivity that is permitted between a BlackBerry® Smart Card Reader and
a computer before the secure pairing information is deleted from the computer and the BlackBerry Smart Card Reader. The
permitted range is 1 through 10,080 minutes.
Activity is any secure packet that is sent or received by a BlackBerry device and a BlackBerry Smart Card Reader over a Bluetooth®
connection, other than the connection heartbeat packet.
Default value
The default value is a null value. The secure pairing information is not deleted from the computer.
Usage
If you configure this rule, the user cannot turn off this feature but can change the Inactivity Timeout field in the BlackBerry Smart
Card Reader options on the computer to a lower value.
If you do not configure this rule, the user can change the Inactivity Timeout field to any value.
Minimum requirements
BlackBerry® Enterprise Server version 4.0 SP5
BlackBerry Smart Card Reader software version 1.5
Exceptions
The BlackBerry® Enterprise Server for Novell® GroupWise® does not support this rule.

Maximum PC Disconnected Timeout IT policy rule

Description
This rule specifies the maximum time (in seconds) that can elapse after a computer and a BlackBerry® Smart Card Reader close
a Bluetooth® connection before the secure pairing information for that connection is deleted from the computer and BlackBerry
Smart Card Reader. The permitted range is 0 through 604,800 seconds.
Default value
62