Battery Capacity

The batteries are 1.6Ah Nickel Metal Hydride cells. The number of hours operation on a
full charge is totally dependant upon the type of use to which the unit is put.
Transmissions use by far the greatest power, but with test calls set at 1 hour, the cells
should last several days between charges. Turning off the unit between use is
recommended, but it should be noted that long periods of no use will still reduce the
battery charge.
The battery indicator on the display will show the approximate capacity left in the cells.
At a preset point the unit will transmit a "Battery Low" message, flash the display
backlight and beep (if selected). When the battery voltage falls below that required to
run the transmitter, the unit will flash the display and the battery icon, then it will
automatically switch itself off, since it cannot perform its intended function without a
transmitter. It will then need recharging before it can be used again.

Specification

Power:
System Power Consumption:
Charger Input:
Transmitter:
Power output:
Frequency Range:
Channel Spacing:
TX Baud Rate:
RF Standards applied:
Type Designation:
Notified Body Ref. No:
EMC Standards applied:
LVD Standards Applied
Scope's policy is one of continuous development and specifications are subject to change without notice
HHTXMK2
2.4V (1.2V x 2) NiMh cells, sealed pack
less than 2mA (standby), 180mA (transmit)
5 V dc @ 2A
500mW max
450-470 MHz
12.5 KHz
1200
ETS 300 220
MOBILINK
0891
EN 301 489-1 V1.4.1
EN 60950: 2000