Datasat AP20 Installation And Operating Manual page 91

Audio processor
Table of Contents

Advertisement

Mid Frequency
Figure 69. Example – Mid Frequency Crossover Setup
As shown in Figure 69, set output channel
channel is still set to
Set the low pass filter to the mid range driver's upper crossover point, which in this case is
1200Hz.
Set the high pass filter to the mid range driver's lower crossover frequency, which in this case is
350Hz.
Set the slope to 24dB/octave.
Set the crossover ID to
High Frequency
Figure 70. Example – High Frequency Crossover Setup
As shown in Figure 70, set output channel
channel is still set to
Set the high pass filter to the high range driver lower crossover frequency, 1200Hz.
AP20 Installation & Operating Guide
AP20 Installation and Operating Guide
2
1
(or left channel, remember, left = channel 1 in the example).
M
to identify it as the midrange frequency output for channel two (2).
3
1
(or left channel, remember, left = channel 1 in the example).
for the mid range driver. Make sure the input
for the high range driver. Make sure the input
Document # 9301H39200 Ver. 1.25
Page 91

Hide quick links: