Drain Information And Plumbing - Jacuzzi J-ALLURE J-ALLURELuxury Bathing and Entertainment System Installation And Operation Instructions Manual

Luxury bathing and entertainment system
Table of Contents

Advertisement

J-Allure
Service Access
The skirt fits along the front of the bath and is an access panel for servicing. Allow a space of at least 8 inches away
from the bath for skirt removal. To remove the skirt, remove the screws at the bottom of the skirt and withdraw the
skirt.
Bath Electrical Connections
A separate circuit, which must be protected by a Ground Fault Circuit Interrupter (GFCI), is required. Install a duplex
outlet (not provided) to the studwall underneath the bathtub, at least 4 inches above the floor.
CAUTION: Operating the motor/pump without enough water in the bath can cause leaking and permanent
damage to the pump. Before power is applied to the installation, make sure the switch is in the OFF position
to avoid pump damage.
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit
Interrupter.
Drain Information
A drain/overflow assembly must be installed on the bath, water tested, and connected to the sanitary system of the
house. After opening the carton, inspect for damage and verify that the kit is of the proper finish. In the Jacuzzi
Whirlpool Bath drain/overflow kit, note that the waste flange, strainer, overflow cover and cover screws are packaged
in a separate package within the kit to protect the trim finish. Follow the installation instructions provided with the drain/
overflow kit.
After the drain is fully installed, test for proper drainage. If the unit does not drain properly, rectify this condition before
proceeding with the installation. Jacuzzi Whirlpool bath is not responsible for removal and/or reinstallation costs.
NOTE: Watertight installation of the drain is the installer's responsibility. Drain leakage is excluded from the
Jacuzzi Whirlpool Bath warranty of this product.
Plumbing
Pump, jets, and suction fittings for the whirlpool system are factory plumbed in schedule 40 PVC piping. All Jacuzzi
Whirlpool Bath products are factory tested for proper operation and watertight connections prior to shipping.
Before securing the bath to the floor a test for possible water leaks must be made. Fill the bath and check for leaks.
If leaks are detected, notify your Jacuzzi Whirlpool Bath Dealer. Do not install the unit.
FINISHED
WALL
3 PRONG
PLUG
DUPLEX
RECEPT.*
FLOOR
4" MIN.
FROM J-BOX
*(NOT PROVIDED)
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

J-allure

Table of Contents