IV. Installation Issues

IV. Installation Issues
IVA. Location Requirements
See attached installation instructions.
IVB. Electrical Requirements
See attached installation instructions.
IVC. Water/Drain Requirements
See attached installation instructions.
IVD. Shipping/Packaging Removal
See attached installation instructions.
IVE. Installation Related Process
1.
Leveling cabinet –
2.
Leveling doors –
see installation instructions.
3.
Installing handles –
4.
Door reversal –
5.
Quick test procedure
Top Ten Cosmetic/Customer Use/Installation Issues
Top Ten Cosmetic/Customer Use/Installation Issues
Not cleaning sump filters....
Smelly dishwashers....
missing or drain gases being present. If all else is OK, then problem can be preservative not purged
from tank door gasket.
Doors leaking or not latching....
installed before dishwashers are leveled front to back, tanks & doors out of square, wooden doors
not drilled accurately). Can be blockage in condensation tubes or having condensation tubes
connected to drain hose air gaps.
Inner door damage....
(dishwashers clamped on wrong sides or dropped).
Doors hit toe kicks....
Junction boxes....
Dispensers....
close the door.
Drain hoses not installed properly....
causes poor draining & smelly dishwashers. Most drain pumps are mistakenly replaced for drain
hose installation issues.
Outer doors....
Damaged water valves....
can allow some water onto kitchen floors.
See attached installation instructions.
not required for steel doors. For wooden panels added to steel doors,
See attached installation instructions.
not possible or necessary.
Customers often don't know they exist.
Often occurs from filters not being cleaned, drain hose high loops
From upper rack during improper shipping and handling
Toe kick installation issue.
Comes from wires not being connected correctly during installation.
Customers using too much detergent, not using rinse-aid & not knowing how to
Most are dinged during shipment.
Primarily from fittings being overtightened. A damaged valve
:
:
Usually an installation issue (dishwasher brackets
Often no air gap or high loop + pinched hoses --