Lighting & Operating Instructions - Vermont Castings LHERDV20 Owners Installation And Operating Manual

Vermont castings direct vent insert - homeowner's installation and operating manual
Table of Contents

Advertisement

Lighting and Operating Instructions
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. ��his heater has a pilot which must be lit manually. When
lighting the pilot follow these instructions exactly.
B. B��FOR�� LIGH��ING smell all around the heater area
for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
1. STOP! Read the safety information above.
. ��urn off all electrical power to the fireplace.
3. For MN/MP/��N/��P appliances ONLY, go on to �tep
4. For RN/RP appliances turn the On/Off switch to
"OFF" position or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to "OFF".
Euro SIT
SIT NOVA
6. Wait five (5) minutes to clear out any gas. ��hen smell
for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information above.
If you do not smell gas, go to the next step.
7. Remove glass door before lighting pilot. (�ee Glass
Frame Removal section).
8. Visibly locate pilot by the main burner.
9. ��urn knob on gas control counterclockwise
"PILOT".
1. ��urn the On/Off switch to "OFF" position or set the
thermostat to lowest setting.
. ��urn off all electric power to the fireplace if service is
to be performed.
10004894
FOR YOUR SAFETY READ BEFORE LIGHTING
Lighting Instructions
OFF
Honeywell
FP1067
lighting instruction
knobs
3/9/01 djt
To Turn Off Gas To Heater
If you cannot reach your gas supplier, call the Fire
Department
C. �se only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, do not try to repair it, call a qualified
service technician. Applying force or any attempted
repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician
to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
10. Push the control knob all the way in and hold. Im-
mediately light the pilot by repeatedly depressing the
piezo spark ignitor until a flame appears. Continue
to hold the control knob in for about one (1) minute
after the pilot is lit. Release knob and it will pop back
up. Pilot should remain lit. If it goes out, repeat steps
5 through 8.
3/8" - 1/2"
If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
If after several tries, the pilot will not stay lit, turn
the gas control knob to " " and call your service
technician or gas supplier.
11. Replace glass door.
1. ��urn gas control knob to "ON" position.
13. For RN/RP appliances turn the On/Off switch to "ON"
to
position or set thermostat to desired setting.
14. ��urn on all electrical power to the fireplace.
3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Close control access panel.
LHEDV Series Direct Vent Insert
FP1068
Lighting instructions
Pilots
17