Installation of Trim Switch
for RN/RP Gas Valves
1. ��hread wire through openings on the right side of fire-
place. Do not cut wire or insulation on metal edges.
. Insert ON/OFF switch with wiring assembly into the
bracket switch with the pre-punched opening mounted
on the right side of the trim. (Fig. 7)
3. For left side installation, relocate the bracket switch to
the left side of the trim kit and repeat �tep . (Fig. 8)
4. Connect wiring from the switch to the gas valve (Fig.
9a & b).
Right Side Installation
On/Off
�witch As-
sembly
Wiring from
Millivolt Gas
Fig. 7 Insert ON/OFF switch with wiring assembly into
bracket switch.
FP1330
Switch assy
4/03
Fig. 8 For left side installation, reverse switch position in
bracket.
SIT Valve
��hermopile
FP1331
on/off switch
4/03
FP38a
Fig. 9a On/Off switch or millivolt thermostat.
FP382a
REMOTE SWITCH WIRING - NVC
10004894
1/03
Left Side Installation
�witch As-
Valve
Fig. 9b On/Off switch wiring.
CAUTION: Do not wire millivolt remote wall
switch for gas fireplace to a 120v power
supply.
1. ��he fireplace may be installed in and vented through
On/Off
any solid fuel fireplace that has a minimum fireplace
opening 5¹⁄₄"W x 17¹⁄x" H x 13¹⁄x"D
sembly
for LH��CDV0 and LH��RDV0 or 8³⁄₄"W x 1"H
mm)
x 15¹⁄x"D
LH��RDV30 and has been installed in accordance with
the National, Provincial/�tate and local building codes
and is constructed of noncombustible materials.
FP1330
. Only H��DVR�� RD vent termination kit, H��DV�� (8 x
1) or H��DV�� (1 x 1) termination kit and flex vent kit
H��DVK5 or H��DVK35 are to be use din this installation.
Under no circumstances should B vent or C vent be
used on this application.
3. Any flue damper must be removed or blocked open.
5. ��he chimney must be clean and in good working order
and constructed of noncombustible materials.
6. Make sure that all chimney cleanouts fit properly so air
cannot leak into the chimney.
7. Install the appliance without trim frame and make all
gas fittings and electrical connections.
8. Install the decorative trim frame. Please refer to the
FP1331
Frame Assembly instructions.
Installer must attach red warning plate with
screws supplied with the gas fireplace insert
to the inside of the firebox of the fireplace into
which the gas fireplace insert is installed.
Cutting any sheet metal parts of the fireplace,
in which the gas fireplace insert is to be in-
stalled, is prohibited.
If the factory-built fireplace has no gas ac-
cess hole(s) provided, an access hole of
1¹⁄₂" (38 mm) or less may be drilled through
the lower sides or bottom of the firebox in a
proper workmanship-like manner. This access
hole must be plugged with a noncombustible
insulation after the gas supply line has been
installed.
LHEDV Series Direct Vent Insert
Honeywell Valve
Venting Installation
FP1218
Remote switch
wiring
8/02
for LH��CDV30 and
(730 x 533 x 394 mm)
FP118
(641 x 438 x 343
9