S
R
TART
ELAY
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1. Check between "2" and "4" on relay (with relay unplugged). If there is continuity replace the relay, as the relay
contacts should be open.
2. Check between "3" and "4" on relay, if no continuity replace the relay.
T
R
G
O
EPLACE
EARMOTOR
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1. Disconnect the transmission cable from the electrical box.
2. Remove the 4 hex head bolts securing the evaporator to the top of the transmission.
3. Remove the 4 bolt's holding the transmission and bracket to frame base, while supporting the weight of the
evaporator. Remove the transmission from the unit.
4. When replacing the transmission, it may be necessary to rotate the auger back and forth to align the motor
shaft and auger.
© 2004-2014, Cornelius Inc.
Figure 14. Gearmotor Assembly
A
SSEMBLY
- 17 -
Continuous Flow Icemaker Service Manual
Publication Number: 630460174SER