Pll Adjustments - Icom IC-756PRO Service Manual

Hf/50mhz all band transceiver
Hide thumbs Also See for IC-756PRO:
Table of Contents

Advertisement

4-2 PLL ADJUSTMENTS

ADJUSTMENT
ADJUSTMENT CONDITION
1
• Display frequency: Any
REFERENCE
FREQUENCY
• Turn L52 on the PLL unit to 4 rota-
tion downside for presetting.
• Receiving
2
1
• Display frequency: 0.030000 MHz
LPL-A LOCK
VOLTAGE
• Mode
• Receiving
1
• Display frequency: 14.999999 MHz
VCO-A LOCK
VOLTAGE
• Mode
• Receiving
2
• Display frequency: 19.999999 MHz
• Mode
• Receiving
3
• Display frequency: 44.999999 MHz
• Mode
• Receiving
4
• Display frequency: 60.000000 MHz
• Mode
• Receiving
1
• Display frequency:
1LO-A
OUTPUT
0.030000 MHz, 7.999999 MHz
LEVEL
8.000000 MHz, 19.999999 MHz
20.000000 MHz, 44.999999 MHz
45.000000 MHz, 60.000000 MHz
• Receiving
LPL-B LOCK
1
• Sub display freq. : 0.030000 MHz
VOLTAGE
• Mode
• Receiving
VCO-B LOCK
1
• Sub display freq. : 7.999999 MHz
VOLTAGE
• Mode
• Receiving
2
• Sub display freq. : 19.999999 MHz
• Mode
• Receiving
3
• Display frequency: 44.999999 MHz
• Mode
• Receiving
4
• Display frequency: 60.000000 MHz
• Mode
• Receiving
1LO-B
1
• Sub display freq. :
OUTPUT
0.030000 MHz, 7.999999 MHz
8.000000 MHz, 19.999999 MHz
LEVEL
20.000000 MHz, 44.999999 MHz
45.000000 MHz, 60.000000 MHz
• Receiving
3LO
1
• Display frequency: Any
• Receiving
OUTPUT
LEVEL
S3LO
1
• Display frequency: Any
OUTPUT
• Receiving
LEVEL
MEASUREMENT
UNIT
PLL
PLL
: USB
PLL
: USB
: USB
: USB
: USB
PLL
PLL
: USB
PLL
: USB
: USB
: USB
: USB
PLL
PLL
PLL
4 - 2
LOCATION
Connect a frequency
64.000000 MHz
counter
to
check
point P81.
Connect an RF volt-
Maximum level
meter to check point
(0 dB or more)
P81.
Connect
a
digital
multimeter or oscillo-
scope to check point
LPA.
Connect
a
digital
multimeter or oscillo-
scope to check point
LVA.
Connect an RF volt-
0 dBm or more
meter to check point
P351.
Connect
a
digital
multimeter or oscillo-
scope to check point
LPB.
Connect
a
digital
multimeter or oscillo-
scope to check point
LVB.
Connect an RF volt-
0 dBm or more
meter to check point
P651.
Connect an RF volt-
–16 dBm or more
meter to check point
P701.
Connect an RF volt-
–7 dBm or more
meter to check point
P801.
ADJUSTMENT
POINT
VALUE
UNIT
ADJUST
PLL
adjustment)
2.0 V
PLL
4.3 V
PLL
4.3 V
4.3 V
4.3 V
2.0 V
PLL
4.3 V
PLL
4.3 V
4.3 V
4.3 V
L52
(R33
for critical
L81, L82
C154
C278
C258
C228
C208
Verify
C454
C578
C558
C528
C508
Verify
Verify
Verify

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents