MICROPROCESSOR CONTROL

WIRELESS REMOTE CONTROLLER

INDOOR UNIT DISPLAY SECTION
OPERATION INDICATOR lamp
The operation indicator at the right side of the indoor
unit indicates the operation state.
Operation Indicator
Operation state
Indication
This shows that the air
conditioner is operating
to reach the target temp-
erature.
Please wait until the
target temperature is
obtained.
This shows that the
room temperature is
approaching the target
temperature.
CLOCK
CLOCK
RESET
RESET
lighting
not lighting
Difference
between set
temperatuer
and room
temperature
Approx. 2 :
or more
Approx. 2 :
or less
MCF-13NV -
E3
Once the operation mode are set, the same operation mode
can be repeated by simply turning the
OPERATE/STOP(ON/OFF) button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minutes time delay will operate
to protect system from overload and compressor will not
restart for 3 minutes.
9-1. "I FEEL CONTROL" (
(1) Press OPERATE/STOP(ON/OFF) button on the remote
controller. OPERATION INDICATOR lamp of the indoor
unit turns on with a beep tone.
(2) Select "I FEEL CONTROL" (
OPERATION SELECT button.
(3) The operation mode is determined by the room
temperature at start-up of the operation.
Initial room temperature
25: or more
more than 13:,
less than 25:
Once the mode is fixed, the mode does not change by
room temperature afterwards.
Under the ON-TIMER (
determined according to the room temperature at set
time the operation starts.
When the system is stopped with the
OPERATE/STOP(ON/OFF) button on the remote
controller, and restarted within 2 hours in "I FEEL
CONTROL" (
)mode, the system operates in previous
mode automatically regardless of the room temperature
Example
Previous operation
COOL mode of
"I FEEL CONTROL"
or COOL mode
When the system is restarted after 2 hours and more, the
operation mode is determined by the room temperature at
start-up of the operation.
Example
Previous operation
COOL mode of "I FEEL
CONTROL" or COOL
mode
15
) OPERATION
)mode with the
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
)operation, mode is
Restart
COOL mode of
"I FEEL CONTROL"
Restart
COOL or DRY mode of
"I FEEL CONTROL" that
is determined by room
temperature at start-up
of the operation.
.