Errors And Self Diagnosis - Fujitsu AUT36A Operating Manual

Air conditioners cassette type
Table of Contents

Advertisement

ERRORS AND SELF DIAGNOSIS

1
2
TIMER
SET TIME
TEMP./DAY
MODE
CLOCK ADJUST
ZONE
SET
If there is a problem with the air conditioner, it will stop run-
ning and "EE: EE" will be displayed instead of the clock.
(1) If the operation lamp is on then press the START/
STOP button to turn it off.
(2) Press the SET TIME (▼) and the SET TEMP./DAY (▼)
buttons at the same time for more than three seconds
to start the self diagnosis check.
An error code will be displayed in the clock display area.
(3) Press the SET TIME (▼) and the SET TEMP./DAY (▼)
buttons again for more than three seconds to end the
self diagnosis check.
Error Code
AUTO
AUTO
DEFROST TEST
FAN
CONTROL
MASTER
CONTROL
ENERGY SAVE
START/STOP
DAY OFF
Error Code
Communication error
(indoor unit
Communication error
(indoor unit
Room temperature sensor open
Room temperature sensor shortcircuited
Indoor heat exchanger temperature
sensor open
Indoor heat exchanger temperature
sensor shortcircuited
Outdoor heat exchanger temperature
sensor open
Outdoor heat exchanger temperature
sensor shortcircuited
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor
shortcircuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor
shortcircuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal