Adjustment Procedures; Pll And Transmitter Adjustments - Icom IC-A22 Service Manual

Vhf air band transceivers
Hide thumbs Also See for IC-A22:
Table of Contents

Advertisement

SECTION 4

4-1 PLL AND TRANSMITTER ADJUSTMENTS

ADJUSTMENT
ADJUSTMENT CONDITIONS
TUNE
1 •
Displayed frequency
VOLTAGE
Receiving
REFERENCE
1 •
Displayed frequency
Connect the RF power meter or a 50 Ω
FREQUENCY
dummy load to the antenna connector.
Transmitting
POWER
1 •
Displayed frequency
Apply no AF signal to the [MIC] jack.
Transmitting
MODULATION 1 •
Displayed frequency
R5047, R5098
Connect the AG to the [MIC] jack and
set as;
Frequency
Level
Transmitting
2 • Set the AG as;
Level
SIDE TONE
1 •
Connect the AG to the [MIC] jack and
set as;
Frequency
Level
Transmitting

ADJUSTMENT PROCEDURES

: 118.025 MHz
: 136.975 MHz
pannel
: 118.025 MHz
pannel
: 136.975 MHz
: Center
pannel
: 1 kHz
: 200 mV
: 20 mV
pannel
: 1 kHz
: 200 mV
4 - 1
MEASUREMENT
UNIT
LOCATION
RF
Connect the digital
multimeter or oscillo-
scope to CP2 (TUNE).
Top
Loosely couple the
frequency counter to
the antenna connec-
tor.
Top
Connect the RF power
meter to the antenna
connector.
Top
Connect the modula-
tion analyzer to the
antenna connector via
an attenuator.
Top
Connect the AC mil-
livoltmeter with an 8 Ω
dummy load to the
[SP] jack.
ADJUSTMENT
POINT
VALUE
UNIT ADJUST
1.4–1.6 V
RF
R4068
136.975000 MHz
RF
C4101
±400 Hz
1.5 W
RF
R4057
(Carrier power)
85%
MAIN
R5098
30%
MAIN
R5047
20 mW (0.4 V) MAIN
R5087

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-a22eIc-a3Ic-a3e

Table of Contents