Tumbler Enclosure - IPSO TMB795C Planning Manual

50 and 75 pound tumblers on-premise laundry planning handbook
Table of Contents

Advertisement

Tumblers – 50 and 75

Tumbler Enclosure

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.
NOTE: Shaded areas indicate adjacent structure.
1
0.5 in. (13 mm) recommended between machines for removal or installation
2
Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
3
4 in. (102 mm) maximum header thickness
4
12 in. (305 mm) minimum clearance permitted for remainder
5
Guard
6
Provision for make-up air
7
24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
8
0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
11
1
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
3
2
Figure 1
W056
4
5
6
7
TMB2131N
TMB2131N
4-08-44