To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances.
NOTE: Shaded areas indicate adjacent structure.
1
0.5 in. (13 mm) recommended between machines for removal or installation.
2
Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
3
4 in. (102 mm) maximum header thickness
4
Minimum clearance permitted for remainder: Gas 4 in. (102 mm), Steam 12 in. (305 mm)
5
Guard
6
Provision for Make-Up Air
7
24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
8
0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed