Tumblers – T30 and T45
For T45 Gas Models (For Total Machine):
Serial Plate
Voltage
208–240V/60Hz/1ph L1, L2, Neutral and ground
200–208V/60Hz/3ph
240V/60Hz/3ph
200V/50Hz/1ph
230-240V/50Hz/1ph
19
Terminal Block
Connections
Required
L1, L2, L3 and ground
L1, L2, L3 and ground
L1, Neutral and ground
L1, Neutral and ground
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Recommended Fuse
Current
or Breaker Rating
(Amps)
(Amps)
12.0
15
9.6
15
9.6
15
11.2
15
10.8
15
Table 5
Recommended
Minimum
Breaker
Conductor Size
Poles
2
(AWG [mm
])
2
14 (2.08)
3
14 (2.08)
3
14 (2.08)
1
14 (2.08)
1
14 (2.08)
4-08-43