Junction Box Wiring Installation Instructions; Optional Brick Liner Installation Instructions - Empire Comfort Systems DVP36FP3 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36FP3:
Table of Contents

Advertisement

JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL
LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN
POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCOR-
DANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA
70 (LATEST EDITION).
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction box and
attached to the receptacle that is provided. Leave approximately
6" of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
Attention: A Junction box is located on the lower left side of the
fireplace for direct ignition connections on direct ignition fireplace
models only.

OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS

1. Using gloves, unpack liner components and check for damaged
or missing components.
2. Lower bottom louver and remove upper louver on fireplace.
3. Remove glass frame assembly from fireplace.
4. Remove rear logs from burner assembly.
5. Place brick panel (rear) against rear wall in fireplace.
Note: The top edge will have a half-moon cutout relief to match
up with the rear flue vent hole.
6. While holding finished edge on brick panel (side), place brick
panel (sides) against side walls in fireplace. Move side panels
rearward until the back edge meets the rear brick panel. Slide
Page 70
side brick panels down so they rest on firebox bottom.
7. Align grout lines on top brick panel with the grout lines on the
side brick panels. Place the top brick panel into brick panel
holder. With needle-nose pliers, carefully bend hold-down tabs
on brick panel holder over the edges of the top brick panel. The
hold-down tabs will securely hold the top brick panel in place.
8. Replace rear logs onto burner assembly. Refer to log
placement, page 43.
9. Attach glass frame assembly onto fireplace.
10. Raise bottom louver and replace top louver onto fireplace.
11. Installation of optional brick liner is complete.
*
31447-5-0214