Message number Error message
WARN_22
DEVICE ERROR
WARN_23
CONNECTOR DETACHED
WARN_24
CONNECTOR DETACHED
WARN_25
CONNECTOR DETACHED
WARN_26
DOUSER ERROR
WARN_27
BALLAST ERROR
WARN_28
BALLAST ERROR
FAILURE: Danger level – Low
Message number
Error message
FAIL_01
TEMPERATURE ERROR
FAIL_02
TEMPERATURE ERROR
FAIL_03
TEMPERATURE ERROR
FAIL_04
TEMPERATURE ERROR
FAIL_06
TEMPERATURE ERROR
FAIL_10
TEMPERATURE ERROR
FAIL_11
TEMPERATURE ERROR
FAIL_12
TEMPERATURE ERROR
FAIL_13
TEMPERATURE ERROR
FAIL_15
TEMPERATURE ERROR
FAIL_16
LENS ERROR
FAIL_17
LENS ERROR
FAIL_18
LENS ERROR
FAIL_19
LENS ERROR
FAIL_21
ADJUSTMENT ERROR
FAIL_24
ADJUSTMENT ERROR
FAIL_25
DEVICE ERROR
FAIL_26
DEVICE ERROR
FAIL_27
DEVICE ERROR
FAIL_28
DEVICE ERROR
FAIL_29
DEVICE ERROR
FAIL_30
BALLAST ERROR
FAIL_34
ADJUSTMENT ERROR
FAIL_35
ADJUSTMENT ERROR
FAIL_36
DEVICE ERROR

Information Messages

The message number is not displayed for information messages. Check the following if a message appears in the STATUS
MESSAGE window.
Message
DOUSER CLOSED
LAMP POWER + LIMIT
24
Messages
Meaning
Failure of the peltier B control
The peltier R connector disconnected
The peltier G connector disconnected
The peltier B connector disconnected
Trouble with the douser operation
Failure of the ballast communication for the lamp power
Incorrect settings of the lamp S/N or the lamp power wattage
Meaning
Temperature of the system area is too high.
Temperature of the projector head area is too high.
Temperature of the power area is too high.
Temperature of the intakes is too high.
Temperature of the optical unit area is too high.
Warning for abnormal temperature of Panel R
Warning for abnormal temperature of Panel G
Warning for abnormal temperature of Panel B
Warning for abnormal temperature of the lamp
Warning for abnormal temperature of the lamp power
Failure of the zoom position adjustment to the registered setting
Failure of the lens focus adjustment to the registered setting
Trouble with the zoom position adjustment
Trouble with the lens focus adjustment
Abnormal in the Z-axis adjustment
Failure of calibration for luminance deterioration
Failure of FPGA configuration
Trouble with the IIC circuit
Trouble with the LVDS circuit
Trouble with the PLL circuit
Trouble with the PARITY circuit
Lamp power interlocked
Deviation of the Z-axis operation for + direction
Deviation of the Z-axis operation for – direction
Error of the DVI setting
Meaning
Douser is closed.
Lamp power was automatically adjusted by correcting luminance
deterioration, but the picture is not brighter.