Information Messages - Sony SRX-R320 Operating Instructions Manual

Digital cinema projector
Hide thumbs Also See for SRX-R320:
Table of Contents

Advertisement

Available languages

Available languages

Message number Error message
WARN_29
EXHAUST ERROR
WARN_30
COVER DETACHED
WARN_31
FAN ERROR
WARN_32
FAN ERROR
WARN_33
FAN ERROR
FAILURE: Danger level – Low
Message number
Error message
FAIL_02
TEMPERATURE ERROR
FAIL_04
TEMPERATURE ERROR
FAIL_06
TEMPERATURE ERROR
FAIL_10
TEMPERATURE ERROR
FAIL_11
TEMPERATURE ERROR
FAIL_12
TEMPERATURE ERROR
FAIL_15
TEMPERATURE ERROR
FAIL_16
LENS ERROR
FAIL_17
LENS ERROR
FAIL_18
LENS ERROR
FAIL_19
LENS ERROR
FAIL_21
ADJUSTMENT ERROR
FAIL_24
ADJUSTMENT ERROR
FAIL_25
DEVICE ERROR
FAIL_26
DEVICE ERROR
FAIL_27
DEVICE ERROR
FAIL_28
DEVICE ERROR
FAIL_29
DEVICE ERROR
FAIL_30
BALLAST ERROR
FAIL_34
ADJUSTMENT ERROR
FAIL_35
ADJUSTMENT ERROR
FAIL_36
DEVICE ERROR

Information Messages

The message number is not displayed for information messages. Check the following if a message appears in the STATUS
MESSAGE window.
Message
DOUSER CLOSED
LAMP POWER + LIMIT
LAMP POWER – LIMIT
LOW REAL TIME CLOCK
BATTERY
LUMI VALUE + LIMIT
LUMI VALUE – LIMIT
20
Messages
Meaning
Abnormal air volume of the outside duct
Filter duct is detached
Abnormal in fan for PS2
Abnormal in fan for PS1
Abnormal in fan for PBS
Meaning
Warning for abnormal temperature of 8-inch duct
Temperature of the intakes is too high.
Temperature of the optical unit area is too high.
Warning for abnormal temperature of Panel R
Warning for abnormal temperature of Panel G
Warning for abnormal temperature of Panel B
Warning for abnormal temperature of the lamp power
Failure of the zoom position adjustment to the registered setting
Failure of the lens focus adjustment to the registered setting
Trouble with the zoom position adjustment
Trouble with the lens focus adjustment
Abnormal in the Z-axis adjustment
Failure of calibration for luminance deterioration
Failure of FPGA configuration
Trouble with the IIC circuit
Trouble with the LVDS circuit
Trouble with the PLL circuit
Trouble with the PARITY circuit
Lamp power interlocked
Deviation of the Z-axis operation for + direction
Deviation of the Z-axis operation for – direction
Error of the DVI setting
Meaning
Douser is closed.
The setting for lamp power (sum of the lamp power and luminance control) is greater than the maximum
output (100%).
The setting for lamp power (sum of the lamp power and luminance control) is lower than the minimum
output.
The RTC battery (BT200) for the SY board should be replaced.
Correction for luminance deterioration was made, but the picture is not brighter.
Correction for luminance deterioration was made, but the picture is not darker.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents